Ingeteam STORAGE 1Play TL M Manual De Instrucciones página 12

Ocultar thumbs Ver también para STORAGE 1Play TL M:
Idiomas disponibles

Idiomas disponibles

Ingeteam
2 B3/B4850/A48100/POWERBOX BATTERY
This chapter describes the process of connection, switch on and configuration of the ISS 1Play
TL M to work with the B3/B4850/A48100/POWERBOX battery.
2.1
Connecting the battery pack to the inverter
Please, consider the following technical notes:
1) The inverter must be OFF before connecting the battery to the inverter.
2) Connect the DC power wires with 10mm
3) In this manual the CAN communication is done with an Ethernet wire.
2.1.1
Wiring of DC wire
The DC wiring must have terminals on the inverter side, and it must be connected to the inverter
as follows:
1. Pass the wires through the dedicated cable grommet, respecting the polarities.
2. Remove the M5 bolts and connect the wiring to the terminal marked as J105 BATTERY
+ and J106 BATTERY -
3. Tighten the M5 bolts with a torque of 2.5Nm to ensure they are properly fastened. It is
important to not apply excessive tightening torque.
4. Check that the connection is tight