Ingeteam
2 WECO 5K3 LV Battery
2.1
Connecting the battery pack to the inverter
This chapter describes how to connect the ISS 1Play TL M to the WECO 5K3 by DC wire and
communication wire.
Please, consider the following technical notes:
1) The inverter must be OFF before connecting the battery pack to the inverter.
2) The battery "DIP SWITCH" must be configured, as detailed in the battery manual, before
connecting to the inverter.
3) Connect the DC power wires with 6-10mm
4) Connect the CAN Communication wire using, for example, the communication wire
supplied with the battery.
2.1.1
Wiring of DC wire
1. Pass the wires through the dedicated cable grommet, respecting the polarities.
2. Remove the M5 bolts and connect the wiring to the terminals marked as J105
BATTERY + and J106 BATTERY –
3. Tighten the M5 bolts with a torque of 2.5Nm to ensure they are properly
fastened.
4. Check that the connection is tight.
ABH2010IMC23_
Use and settings of the INGECON SUN STORAGE 1Play TL M working with BYD B-BOX
Premium HVS/HVM
ISS 1Play TL M
2
.
12