SAFETY RULES (
5
Check to be sure no one is near the load to be
lifted. Inform others in the area that a lift is to be-
gin. Lift the load 2 to 3 inches (50 to 75 mm) and
then jar the load to insure that adequate holding
power is available.
ALWAYS STAY CLEAR OF THE LOAD.
7
ALWAYS STAY
CLEAR OF THE LOAD.
Guide the load by pushing or pulling the edges.
This keeps the entire body clear of the load at
all times. DO NOT guide the load by pushing
or pulling the Magnet. NEVER get in a position
where a dropped load could cause injury.
CAUTION
800-WMAGNET
)
CONTINUED
NEVER re-energize the magnet until it has been placed in contact with the load to
be lifted. Prematurely energizing the magnet could cause unwanted materials to
be attracted to the magnet or the load to unexpectedly jump to the magnet face.
PERSONAL INJURY MAY RESULT.
6
Lift and move the load SMOOTHLY. Avoid jarring
and swinging the load while it is in transit. KEEP
THE LOAD LEVEL. NEVER let the load come in
contact with any obstruction.
8
Carefully set the load down. De-energize the
magnet by selecting the "PROOF" & "RELEASE."
The red indicator light will fl ash. Hold for two to
three seconds; when released the magnet will
return to the "OFF" position. Then lift the magnet
slightly to be sure the load has been released.