LIFTING GUIDELINES (PLATE)
MAGNET
LOAD
MODELS
THICKNESS
Over 1"
* 1"
CER05
*3/4"
*1/2"
*3/8"
*1/4"
Over 1-1/2"
*1-1/2"
*1"
CER07
*3/4"
*1/2"
*3/8"
*1/4"
Over 2"
*2"
*1-1/2"
CER09
*1"
3/4"
*1/2"
*3/8"
*1/4"
* LIFTING CAPACITY IS AFFECTED BY PEEL AND THICKNESS. SEE NOTES 1 & 4 OF THE "IMPORTANT FACTS" (PAGE 6 & 7) IN THIS MANUAL.
† SEE NOTE 2 OF THE "IMPORTANT FACTS" (PAGE 6) IN THIS INSTRUCTION MANUAL. ALSO READ RECOMMENDED LIFTING PROCEDURES
(PAGE 10).
Values shown are for maximum rated capacities when operating instructions and warnings are followed.
Values are based upon SAE 1020 steel. Higher alloy steels and other magnetic materials will require further reductions of
these rated capacities. See Guidelines for the Reduction of Rated Lifting Capacity on previous page.
14 of 66
CER05, CER07, and CER09 (plate)
CLEAN & SMOOTH
Similar to a Flat
(32 micro-inch RMS)
Ground Surface
.000" Max. Air Gap †
Max. Load
Max. Size
(lbs.)
(ft.)
NEVER LIFT ANY LOAD WITH ANY DIMENSION GREATER THAN 5 FEET
600
600
3 x 4
530
4 x 4
480
4 x 5
400
5 x 5
180
4 x 4
NEVER LIFT ANY LOADS WITH ANY DIMENSION GREATER THAN 6 FEET
1200
1200
4 x 4
1000
4 x 5
850
5 x 5
700
5 x 6
450
5 x 5
200
4 x 4
NEVER LIFT ANY LOADS WITH ANY DIMENSION GREATER THAN 8 FEET
2400
2400
5 x 5
2200
6 x 6
1700
6 x 6
1400
6 x 7
700
5 x 6
525
5 x 6
250
4 x 5
TYPE OF SURFACE CONDITION
RUST OR SCALE
Similar to a Flat Hot
Rolled
Steel Surface
.010" Max. Air Gap †
(.254mm)
Max. Load
(lbs.)
-
400
400
375
350
275
150
-
1100
1100
950
775
650
420
190
-
2300
2300
2100
1550
1300
650
480
220
800-WMAGNET
IRREGULAR OR ROUGH
Similar to a Flat Smooth
.020" Max. Air Gap †
(.508mm)
Max. Size
Max. Load
(ft.)
(lbs.)
-
370
3 x 3
370
3 x 4
350
4 x 4
330
4 x 4
200
3 x 4
125
-
900
4 x 4
900
4 x 5
900
5 x 5
700
5 x 6
550
5 x 5
400
4 x 4
180
-
2000
5 x 5
2000
5 x 6
1800
6 x 6
1400
6 x 7
1250
5 x 6
600
5 x 6
450
4 x 5
200
Cut File
Max. Size
(ft.)
-
3 x 3
3 x 3
4 x 4
3 x 4
3 x 4
-
3 x 4
4 x 5
4 x 5
5 x 5
5 x 5
4 x 4
-
4 x 5
5 x 5
5 x 6
6 x 6
5 x 5
5 x 5
4 x 4