Instructions
Intended Use
This device is intended for medical pur-
poses to illuminate body surfaces. It is
used for non-invasive visual examination
of intact skin.
This battery-operated product is de-
signed for external examination only
within professional healthcare facilities
by medical professionals.
Check the correct operation of the de-
vice before use! Do not use the device if
there are visible signs of damage.
CAUTION: Do not look directly into the
LED light. Patients must close their eyes
during examinations.
Caution: UV Light. Do not look directly
at light.
In case of a serious incident with the use
of this device, notify DermLite imme-
diately and, if required by local regula-
tions, your national health authority.
CAUTION: Do not use the device in fire
or explosive risk area (e.g. oxygen-rich
environment).
WARNING: This product can expose
you to chemicals including methylene
chloride and hexavalent chromium,
which are known to the State of Cali-
fornia to cause cancer or reproductive
toxicity. For more information go to www.
P65Warnings.ca.gov.
Electromagnetic Compatibility
This device complies with the EMC
Emissions and Immunity level require-
ments of the standard IEC 60601-1-
2:2014. The emission characteristics of
this equipment make it suitable for use in
professional healthcare environment as
well as residential environment (CISPR
11 Class B). This equipment offers ade-
quate protection to radio communication
service. In the rare event of interference
to the radio communication service, the
user might need to take mitigation mea-
sures, such as relocating or re-orienting
equipment.
WARNING: Use of this equipment adja-
cent to or stacked with other equipment
should be avoided because it could re-
sult in improper operation. If such use is
necessary, this equipment and the other
equipment should be observed to verify
that they are operating normally.
WARNING: Use of accessories other
than those provided by the manufac-
turer of this equipment could result in
increased electromagnetic emissions or
decreased electromagnetic immunity of
this equipment and result in improper
operation.
WARNING: Portable RF transmitters
should be used no closer than 30 cm (12
inches) to any part of the device. Other-
wise, degradation of the performance of
this equipment could result.
The Lumio UV is a skin examination
device designed to view the skin with
magnification and clarity. A ring made
up of 40 UV LEDs (light emitting diodes)
and a high quality, 75 mm 2x lens with
superb color correction and reduced
image distortion produces an image rich
in surface detail.
Hold the Lumio so that the LEDs are
aimed in the direction of the area to be
examined. Place the device approxi-
mately 3-5" (¶5-125 mm) from the skin.
Push the power button (A) at the left side
of the unit to activate the LEDs. Look
through the lens with your eye placed
4-6" (~100-150 mm) above the Lumio.
Move the device closer or further away
from the skin to obtain the desired image
focus and field of view.
Replacing the Batteries
Lumio is designed to work with either
lithium-ion, alkaline, or NiMH recharge-
able AA sized batteries. Disposable
lithium-ion batteries are recommended
for best lighting performance and longest
battery life. The lithium-ion AA batter-
ies provide approximately 2 hours of
continuous operation, or enough power
for performing approximately 240 exams
at 30 seconds per examination. Once
the batteries are depleted, an orange
low battery orange indicator light (B) will
illuminate. To replace the batteries, open
the battery door (C) by sliding it towards
the end of the handle. Remove all four
batteries and insert four new AA batter-
ies with their positive (+) and negative (-)
ends positioned as shown on the inside
of the battery compartment. Lithium-ion
AA batteries are available at most cam-
era stores or directly from DermLite.
Troubleshooting
Please check www.dermlite.com for the
most current troubleshooting informa-
tion. If your device requires servicing,
visit www.dermlite.com/service or con-
tact your local DermLite dealer.
Care and Maintenance
CAUTION: No modification of this equip-
ment is allowed.
Your device is designed for trouble-free
operation. Repairs shall be made only by
qualified service personnel.
Cleaning
The exterior of your device, except the
optical parts, may be wiped clean with
isopropyl alcohol (70% vol.) prior to
use on a patient. The lens should be
treated as high-quality photographic
equipment and should be cleaned with
standard lens cleaning equipment and
protected from harmful chemicals. Do
not use abrasive material on any part of
the equipment or immerse the device in
liquid. Do not autoclave.
Lumio UV components include:
40 UV-LEDs, 75 mm lens with 2x mag-
nification, neoprene sleeve, 4 lithium-ion
AA batteries
Warranty: 10 years for parts and labor.
The battery is warranted for 1 year.
Disposal
This device contains electronics and a
lithium-ion battery that must be separat-
ed for disposal and may not be disposed
of with general household waste. Please
observe local disposal regulations.
Technical Description
Visit www.dermlite.com/technical or
contact your local DermLite dealer.