Relative (Zero)
The relative function subtracts a stored value from the present measurement and
displays the result on the meter.
1 Press REL key momentarily to set the relative mode. This will set the display to
2 The relative mode can be set at auto or manual range, but not when an
3 Press REL key momentarily to set the relative mode again.
4 With small capacitance measurement, the display will show a non-zero value
5 Press and hold REL key for more than 1 s to quit relative mode.
Keysight U1701B User's and Service Guide
zero and store the displayed reading as a reference value. The REL annunciator
will be displayed.
overload has occurred.
due to the presence of alligator clip leads. Use the relative function to
Zero-Adjust the display.