since 1928
9 | CARACTERÍSTICAS Y ESPECIFICACIONES TÉCNICAS
9.1 - CURVAS DE DESEMPEÑO
7.5 (10)
ALH65
5.5 (7.5)
4 (5)
Continuo 24/24h
Velocidad de la bomba: (Rpm)
10
20
30
2.3
4.6
6.9
Caudal: m
3
/h (gpm)
(10.2)
(20.5)
(30.4)
(40.5)
1 rpm = 0.230 m3/h = 1.0127 gpm
1 rev = 3.8333 L = 1.0127 gal
15 (20)
ALHX80
11 (15)
Continuo 24/24h
Velocidad de la bomba: (Rpm)
5
10
15
20
2.75
5.5
8.25
11
Caudal: m
3
/h (gpm)
(12.0)
(24.1)
(36.2)
(48.3)
1 rpm = 0.550 m
1 rev = 9.1667 L = 2.4216 gal
18.5 (25)
ALH100
15 (20)
11 (15)
Continuo 24/24h
Velocidad de la bomba: (Rpm)
5
10
15
20
6
12
18
24
Caudal: m
3
/h (gpm)
(26.4)
(52.8)
(79.2)
(105.7)
1 rpm = 1.200 m
1 rev = 20.0000 L = 5.2834 gal
* Uso intermitente: mínimo de 1 hora de parada tras 2 horas de funcionamiento. / * Uso ocasional: máximo de 1 hora al día.
Albinpump.com
ALH
Características / Especificaciones Técnicas
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermitente*
Ocasional*
40
50
60
70
80
90
9.2
11.5
13.8
16.1
18.4
20.7
(50.3)
(60.5)
(70.9)
(81)
(91.3)
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermitente*
Ocasional*
25
30
35
40
45
50
13.75
16.5
19.25
22
24.75
27.5
(60.3)
(72.4)
(84.5)
(96.9)
(109)
(121.1)
3
/h = 2.4216 gpm
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermitente*
Ocasional*
25
30
35
40
45
30
36
42
48
54
(132)
(158.5)
(184.9)
(211.3)
(237.7)
3
/h = 5.2834 gpm
Albin Bomba ALH Manual de instrucciones (es)
11 (15)
ALHX65
9 (12)
7.5 (10)
Continuo 24/24h
0
10
20
Velocidad de la bomba: (Rpm)
10
20
3.4
6.7
Caudal: m
3
/h (gpm)
(15.0)
(29.5)
1 rpm = 0.335 m
1 rev = 5.583 L = 1.4749 gal
18.5 (25)
ALH80
15 (20)
11 (15)
Continuo 24/24h
Velocidad de la bomba: (Rpm)
5
10
15
20
3.5
7
10.5
14
Caudal: m
/h (gpm)
3
(15.4)
(30.8)
(46.2)
(61.6)
1 rpm = 0.700 m
3
/h = 3.0820 gpm
1 rev = 11.6667 L = 3.0820 gal
37 (50)
ALH125
30 (40)
22 (30)
Continuo 24/24h
Velocidad de la bomba: (Rpm)
5
10
15
11
22
33
Caudal: m
/h (gpm)
3
(48.4)
(96.9)
(145.3)
1 rpm = 2.200 m3/h = 9.6863 gpm
1 rev = 36.6667 L = 9.6863 gal
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermitente*
Ocasional*
30
40
50
60
30
40
50
50
10
13.4
16.8
20.1
(44.0)
(59.0)
(73.0)
(88.5)
3
/h = 1.4749 gpm
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermitente*
Ocasional*
25
30
35
40
45
50
17.5
21
24.5
28
31.5
35
(77)
(92.5)
(107.9)
(123.3)
(138.7)
(154.1)
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Intermitente*
Ocasional*
20
25
30
35
40
44
55
66
77
88
(193.7)
(242.1)
(290.6)
(339)
(387.4)