Maintenance Table; Maintenance Interval - Denios 280739 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6.3

Maintenance table

The activities listen in the following may only be implemented by qualified specialist personnel.

Maintenance interval

Before use and/or daily
Monthly
Every six months
Elektrohydraulischer Fassheber
38/84
Affected part
Entire drum lifter
Hydraulic system
Electronics
Emergency turn around button,
horn button
Chains
Batteries
Front and back tires
Lift mast
Hydraulic oil
Chains
Lift mast
Drum grippers
Hydraulic system
Maintenance
Action
Check functionality, clean if ne-
cessary.
Check for leaks and oil stains.
Also re-fasten the valve screws.
Check functionality.
Check functionality.
Check functionality.
g
Check the liquid levels in the
battery. If refilling is required,
only use distilled water.
g
Check that the battery is
clean, carefully clean stained
areas.
g
Check batteries are stable.
Check for wear.
Check for signs of wear. In case
of tears, please contact our After
Sales Service.
Check and refill if necessary.
g
Check chains and connector
pieces for damage.
g
Check for secure fit.
Clean inside and lightly grease.
Check for secure fit and damage.
Load the drum gripper. Then,
drive it up to the final stop and
measure the height difference
after ten minutes. This value
should not exceed 100 mm.