Wire-Free Roller Shade, Model LBMRJ-C
Chassis Installation & Setup Guide
Important Notes: Read Before Installing
A. Plan the installation to maintain sufficient clearance between the shade and
any other object, including window or door trim, ceilings, corners, hardware,
cranks, lock levers, other shades, and drapery.
B. This product is not suitable for mounting in a pocket or recess.
C. This product is battery powered and requires specific installation clearances
to allow battery changes without demounting.
Please refer to the Product Specification Submittal, PN 085708, and
Application Note #802 (both available for download at Lutron.com) for
detailed installation limitations and restrictions.
D. For safety, shades over 48 in (1219 mm) must be installed by two people.
E. The shade system must be mounted to blocking or other suitable structural
material. It is the responsibility of the installer to choose and install fasteners
that are appropriate for the mounting surface such that each shade bracket
can support 400 lbs (181.4 kg).
FCC / IC INFORMATION
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation.
Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user's authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
This Class B digital apparatus complies with Canadian ICES-003.
1.1
MEASURE AND MARK FOR A SINGLE SHADE:
A. Outside Mount – Wall, Ceiling, or Door
1. Measure across the window at the top, and make a mark at the
half-way point.
2. Note the correct bracket-to-bracket width (BtoB), on the shade box label.
3. Measuring from the window center to the left, mark a distance equal to:
BtoB / 2.
4. Repeat the process, measuring from the window center to the right, to
mark the opposite bracket location.
5. Measure from mark to mark, verifying the distance is equal to BtoB,
±1/8 in (3 mm).
1.2
MEASURE AND MARK FOR GANGED SHADES (3-shade example):
1. Measure across the window at the top, and make a mark at the half-way point
(Window Center).
2. Note the correct bracket-to-bracket width (BtoB), on each shade box label, then add
the widths together to get the Total System Width (TSW).
3. Measuring from the window center on a level line to the left, mark a distance equal to:
TSW / 2.
4. Measuring from the mark made in Step 3 on a level line to the right, mark a distance
equal to Shade 1 BtoB.
5. Measuring from the mark made in Step 4 on a level line to the right, mark a distance
equal to Shade 2 BtoB.
6. Measure from end-mark to end-mark, verifying the distance is equal to the TSW,
calculated at Step 2.
2
MOUNT THE SHADE BRACKETS:
NOTE: The mounting holes in all brackets are elongated to allow for adjustment. Confirm that brackets are level and aligned (add shims if necessary), and verify the correct bracket-to-bracket width before tightening the mounting screws.
A. Mount the Idler Bracket
Align the idler bracket with the bracket location mark(s) at the idler side of the window, and mark the mounting hole
locations. Pre-drill pilot holes if appropriate, and fasten the bracket using the mounting screws provided or other fasteners
appropriate for the mounting surface.
End Bracket
Center Bracket
BtoB Mark
BtoB Mark
Socket
Plate
ceiling mount shown
ceiling mount shown
Align the outside edge
Align the center of the
Remove the socket plate screw and separate the socket plate from the
of the bracket on the
bracket foot on the
mounting plate, then align on the marks and secure with 2 screws.
BtoB mark and secure
BtoB mark and secure
Reinstall the socket plate and secure it with the socket plate screw.
with 2 screws
with 4 screws
11/2021
P/N 045893 Rev. A
please read before installing
COMPONENTS:
Electronic Drive Unit (EDU) Model: QSFC-EDU-BP-C | 4.5 – 9.0 V- | 5 W | 6 in-lb (0,68 N•m)
Wall
Operator
Idler
Bracket Kit
(1) Left Bracket & (1) Right Bracket* , according to configuration ordered
each bracket includes one 1 shim; wall and ceiling brackets include foot cover(s)
TOOLS NEEDED:
Power Drill / Driver
B. Inside Mount – Ceiling
1. Note the correct bracket-to-
bracket width (BtoB), on the
shade box label.
2. Measure from jamb to jamb at
the top of the window opening,
verifying the distance is equal to BtoB, ± 1⁄8 in (3 mm).
3. Measuring from the front edge of the window opening toward the window glass, mark the
mounting surface at the desired bracket mounting depth.
C. Inside Mount – Jamb
1. Note the correct bracket-to-
bracket width (BtoB), on the shade
box label.
2. Measure from jamb to jamb at the
top of the window opening, verifying the distance is equal to BtoB, ± 1⁄8 in (3 mm).
3. Measuring down from the top of the window opening, mark each jamb at the desired bracket
mounting height.*
4. Measuring from the front edge of the jamb toward the window glass, mark each jamb at the
desired bracket mounting depth.*
Shade 1 BtoB
Shade 1
Shade 1
left bracket
! CAUTION: RISK OF FALLING OBJECTS. Read and follow all instructions for mounting the shade system. Failure to follow these instructions could result in minor to moderate injury.
Jamb Bracket
Height Mark
Mounting
Depth
Plate
Mark
Window
Room
Worldwide Headquarters | USA
Lutron Electronics Co., Inc.
7200 Suter Road, Coopersburg, PA 18036-1299 USA
Customer Assistance: 1.844.LUTRON1 (588-7661)
PALLADIOM Wire-Free Roller Shade
Ceiling / Door
Center *
Operator
Idler
Center *
* IMPORTANT: A shade ordered with a center bracket specified on the right side (for ganged installation) will include only the bracket specified for the left side.
The center bracket will be included as the left bracket for the next shade (to the right) in the ganged installation. Refer to section 1.2 for additional information.
#2 Phillips Driver Bit
1/8 in (#31) Drill Bit
(correct pilot hole size for the
included mounting screws)
Magnetic #1 Phillips Screwdriver
*
Window Center
Total System Width / 2
Shade 2 BtoB
Shade 2
Shade 1
Shade 2
Shade 2
right bracket
left bracket
right bracket
(center bracket;
(center bracket;
packaged with Shade 2)
packaged with Shade 3)
B. Mount the Operator Bracket
Align the operator bracket with the bracket location mark(s) at the operator side of the window, and mark the mounting hole locations. Pre-drill pilot
holes if appropriate, and fasten the bracket using the mounting screws provided or other fasteners appropriate for the mounting surface.
End Bracket
BtoB Mark
BtoB Mark
BtoB
Mark
wall mount
door mount
Align the outside edge of the bracket on the
BtoB mark and secure with 4 screws
EEA | Netherlands
European Headquarters | United Kingdom
Lutron NL B.V.
Lutron EA Ltd
Herengracht 466
125 Finsbury Pavement, 4th floor, London EC2A 1NQ, UK
1017 CA Netherlands
TEL: +44.(0)20.7702.0657 | FAX: +44.(0)20.7480.6899
(Importer)
Technical Support: +44.(0)20.7680.4481 | FREEPHONE: 0800.282.107
Jamb
Operator Bracket
Slide Ring
Operator
Idler
Wall
Ceiling / Door
Jamb
Tape Measure
Pencil
Level or Laser Level
Important Inside-Mount Clearance Information
ROLLUP RADIUS (RR): Measure the fabric roll diameter (Rollup Diameter; also listed on
the original shade quote). RR = Rollup Diameter / 2.
JAMB BRACKET MOUNTING HEIGHT: To ensure adequate fabric roll clearance, jamb
brackets must be mounted at a distance from the top of the jamb equal to or greater than
the Rollup Radius (RR) minus 1/2 in (13 mm).
MOUNTING DEPTH: To allow
free access to the battery
compartment, the mounting
5/8 in
(16 mm)
Ceiling
depth must be 5/8 in (16 mm)
max.
Bracket
or less.
Jamb
Brackets may be mounted
deeper than 5/8 in (16 mm),
**
but battery access will require
Window
Room
full removal of the shade from
the brackets.
** BOTTOM BAR CLEARANCE: To ensure adequate clearance for the PALLADIOM
bottom bar, the distance from the rear of the bracket to the window must be equal to or
greater than the Rollup Radius (RR) minus 1-1/8 in (29 mm).
For all other bottom bar types (Architectural, Designer, Sealed), the distance from the
rear of the bracket to the window must be equal to or greater than the Rollup Radius
(RR) minus 1-5/8 in (41 mm).
1. Shade BtoB is measured to/from the centerline of
Shade 3 BtoB
2. Individual shade BtoB tolerance is ± 1⁄8 in (3 mm)
3. Inside mount shown - measure-and-mark
Shade 3
4. All inside mounting depth, height, and clearance
Shade 3
Shade 3
left bracket
right bracket
5. Wall-mount center brackets are operator-side
Center Bracket
BtoB Mark
BtoB Mark
BtoB
Mark
wall mount
ceiling
door mount
mount
Align the center of the bracket on the BtoB
mark and secure with 4 screws
The Lutron logo and Palladiom are trademarks of Lutron Electronics Co., Inc., registered in the U.S. and other countries
Duracell is a registered trademark of Duracell U.S. Operations, Inc., RAYOVAC is a registered trademark of Spectrum Brands, Inc.
Mounting Screws
quantity varies
Wall / Ceiling / Door
Bracket Foot Covers
Quantity and type varies
with included brackets
D-Cell Alkaline Batteries
(3, 4, or 6 depending on shade size; available separately)
Lutron recommends Duracell
or RAYOVAC
®
®
Mounting Height
RR – 1/2 in (13 mm)
min.
Jamb
Bracket
Mounting Depth
5/8 in (16 mm) max.
Jamb
**
Window
Room
PALLADIOM
Designer
Architectural
Sealed
full-wrap & half-wrap
Ganged Shades Example:
center brackets
procedure is the same for outside mount
information presented in section 1.1 above is
applicable to inside-mounted ganged shades
reversible - ceiling mount center brackets are not
Jamb Bracket
Height Mark
Depth
Mark
Room
Window
ceiling
mount
Align the Jamb Bracket
on the marks and secure
with 2 screws.
Lutron Electronics Co., Inc. 7200 Suter Road, Coopersburg, PA 18036-1299, U.S.A.