Problem Solving

PROBLEM
Unit fails to start
Filter Pads not
wetting.
Filter pads too wet
Water leaking from
overflow
Water Droplets in
air stream
Excessive humidity
Inadequate
Cooling
Unpleasant Odor
PROBABLE CAUSE
Power Failure
a
b
Tripped Circuit Breaker
c
Blown Fuse
Electrical Fault
d
e
Motor failure
a Pump Seized
b No water restrictor
c Electrical fault with pump
d Needs smaller restrictor
e High voltage in your area
a
Float Valve Leaking
b
Drain from Filter Pads
a
Loose Delivery Tube
b
Break in tubing
c
Pump appears to deliver
excessive water to pads
a
Not enough air flow
b
Inadequate Exhaust
a
Dirty Filters
b
Dry Filters
a Unit located near odor source
b Algae in water tank
ANY FURTHER PROBLEMS PLEASE CONTACT YOUR
BONAIRE CUSTOMER CARE LINE ON 1-800-939-2983
REMEDY
a Wait for power to be turned on.
b Reset circuit breaker
c Replace
d Call Bonaire Care Line
e Change the motor
a
Extension cord dropping voltage
b
Maintenance page. See Pump section.
c
Call Bonaire Care Line
a
Check adjustment or replace float valve
if necessary
b
Normal Operation
adjust float level
a Check and tighten
b Replace as necessary
c. Check the condition of the filter pad.
Wash if pad shows heavy buildup of
minerals
a
Increase fan speed
Provide more open area to exhaust
b
stale air by opening windows and doors
in adjacent rooms.
Clean
a
Check control set on COOL mode.
b
Check water delivery system. Adjust if
necessary.
a
Remove source
b
Clean tank and refill with fresh water.
18