Button combinations
Child safety combination
To lock the control panel, press and hold both buttons
simultaneously for 3 seconds. To unlock the control panel, press
and hold both buttons simultaneously for 3 seconds.
Notes on operation
•
The preset temperature is 12 °C and must be set according to the wine after
commissioning.
•
The cooling temperature can be set from 5-22°C for both the upper and lower
zones. And the temperature of the lower zone can only be set equal to or
higher than the temperature of the upper zone.
Alarm tones
When the system malfunction occurs and an alarm tone sounds, press any button
on the control panel to stop the alarm tone.
Error codes
If the temperature sensor of the upper zone fails, an error code is displayed
E1 for an open circuit.
E2 for a short circuit.
If the temperature sensor of the lower zone fails, an error code is displayed:
E5 for an open circuit.
E6 for a short circuit.
If the defrost sensor fails, an error code is displayed:
E3 for an open circuit.
E4 for a short circuit.