Technical details
Cordless Planer 20V PPHA20-Li B2
Rated voltage
Rated idle speed
Plane width
Cut depth
Fold depth
Maximum high-frequency
output
Battery PAP 20 B3*
Type
Rated voltage
Capacity
Cells
High-speed battery charger PLG 20 C3*
INPUT
Rated voltage
Rated power
consumption
Fuse (internal)
OUTPUT
Rated voltage
Rated current
Charging time
Protection class
* BATTERY AND CHARGER ARE NOT SUPPLIED
Noise and vibration data
Noise measurement value determined in
accordance with EN 62841. The A-rated
noise level of the power tool is typically:
Noise emission value
Sound pressure level
Sound power level
Uncertainty
Wear ear muffs!
PPHA 20-Li B2
20 V
(DC)
n
= 14000 rpm
0
82 mm
0–2 mm
max. 17 mm
10 dBm
LITHIUM ION
20 V
(DC)
4.0 Ah
10
230–240 V ∼ 50 Hz (AC)
120 W
T3.15A
3.15 A
21.5 V
(DC)
4.5 A
approx. 120 min.
II /
(double insulation)
L
= 88.3 dB (A)
PA
L
= 99.3 dB (A)
WA
K = 3 dB
Total vibration value
Handle
Additional handle
Uncertainty
NOTE
►
For an accurate estimate of the vibration load
during a specific working period, the periods
during which the appliance is switched off or
is running but not actually being used must
also be taken into consideration. This can
significantly reduce the vibration load over
the total working period.
►
The vibration emission values and the noise
emission values given in these instructions
have been measured in accordance with a
standardised test procedure and can be used
for comparison of the power tool with another
tool.
►
The specified total vibration values and the
noise emission values can also be used to
make a provisional load estimate.
WARNING!
►
Depending on the manner in which the power
tool is being used and, in particular, the kind
of workpiece being worked, the vibration and
noise emission values can deviate from the
values given in these instructions during actual
use of the power tool. Try to keep the vibra-
tion loads as low as possible. Measures to
reduce the vibration load are, e.g. wearing
gloves and limiting the working time. Wherein
all states of operation must be included (e.g.
times when the power tool is switched off and
times where the power tool is switched on but
running without load).
a
= 3.944 m/s
2
h
a
= 5.950 m/s
2
h
K = 1.5 m/s
2
GB │ IE
│