Refrigerant Piping Connection
When connecting refrigerant piping, do not let substances or gases other than the speci ed
refrigerant enter the unit. The presence of other gases or substances will lower the unit' s capacity,
and can cause abnormally high pressure in the refrigeration cycle. This can cause explosion and
injury.
Note on Pipe Length
Ensure that the length of the refrigerant pipe, the number of bends, and the drop height
between the indoor and outdoor units meets the requirements shown in the following table :
The Maximum Length And Drop Height Based on Models. (Unit: m)
Model
12
18
Note: The pipes in all cases must be copper for refrigerant gas.
CAUTION
Mark the data plate with the Ori ce installed (for some models).
Please purchase the ttings according to the requirements in the manual strictly.
Refer the diagram when installing.
Liquid side
Indoor
Outdoor
Pipes
Max. Length
(m)
Liquid
Gas
1/4"
3/8"
25
1/4"
1/2"
30
Indoor
Drop Height
(m)
10
20
Liquid side
Outdoor
X
78
Refrigerant
Additional
preload (m)
refrigerant (g/m)
5
12
5
12
Liquid side
Indoor
X
Outdoor