2.17. FIRE IN THE EXHAUST. To prevent this situation from happening, observe the instructions set forth under
section 4 on how to install the gas outlet. What to do:
•
The appliance will be turned off due to the excessive temperatures in the exhaust. Do not unplug the
stove.
•
Call fire brigade.
•
The stove must be tested by Chimeney's sweeps after the soot fire, before it is reused.
2.18. Elimination. The stove or boiler cannot be disposed of with household waste when its useful life is over.
Please dispose of the appliance in accordance with the relevant local regulations, in a correct and
environmentally friendly way. Put the product at the end of its useful life in the hands of the waste manager
authorized by the local authorities for transport to a suitable treatment plant.
3.
FUEL.
Your stove is designed to operate with wood pellets (A1); however, it can also work with other biomass fuels
(ask your dealer about this). If using a different type of biomass is possible, select it from the fuel selection menu
(check user manual). In most cases, the combustion basket is not the same as for wooden pellets.
ECOFOREST do not have any control on the quality of the fuel you use. For this reason, ECOFOREST cannot
guarantee the full output of your stove nor the eventual premature aging or eventual damage of the gas outlet. The
fuel's minimum requirements are specified below:
Diameter (mm)
Length (mm)
Granulometry (mm)
Calorific value (Kcal/kg)
Ash (% mass)
Humidity (%mass)
Oils
Burn pot and/or specific strangler.
4.
INSTALLATION.
The below security distances and assembly diagrams are given for information only as an adaptation shall be
made depending on the norms in force regarding gas outlet, power, security minimum distances specific to
geographic areas.
The installation of the stoves must be done in the same way, for this reason, only the París model will be
exposed. In the same way, air inlets and water connections will be missed in all drawings as section 4.19 indicates
the minimum security distances to be respected for their installation.
The power socket to which the stove is plugged should meet the following requirements:
4.1.
Ground connection must comply with the specific applicable regulations.
4.2.
Differential switch with the correct amperage. It must comply with the specific applicable regulations (check
technical specifications of the stove).
4.3.
Single-phase AC of ~230/240V – 50Hz and pure sine wave.
4.4.
The plug must only be connected to a socket with the technical characteristics of the plug in question.
4.5.
Easily accessible power socket. If the power socket can't be accessed due to the characteristics of the
electrical installation, an all-pole disconnection switch must be installed.
4.6.
The power cable provided by ECOFOREST is 1.4m long; you might need a longer one. Always use a cable with
ground plug and with an equal or greater section. Make sure the power cable is not placed under the stove
or close to hot or sharp surfaces that could damage it.
Pellets
6
5-25
— —
≥ 4300
< 1.5
< 12
— —
No oil content
Original
ELECTRICAL CONNECTION.
47
Olive pits
Almond shells
— —
— —
3 - 4
≥ 3800
< 1.5
< 12
Specific
— —
— —
6 - 8
≥ 3700
< 1.5
< 12
— —
Specific