Kongskilde KA 20 Libro De Instrucciones página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
PROBLEM
Motor fails to rotate
The equipment starts,
the flame is ignited and
the equipment blocks
The equipment starts,
the flame does not
ignite and the
equipment blocks
The equipment starts
but combustion is not
correct
The appliance blocks
too soon for tripping of
the thermostat
7. Troubleshooting
CAUSE
- No power
- Faulty cable
- Environment thermostat set too low
- Protection cap of thermostat outlet not
inserted
- The safety thermostat has been tripped
- No oil
- Oil filter clogged
- The oil pump does not build up pressure
- Leaks in oil pipes
- Burner nozzle clogged
- Ignition defect or electrodes in incorrect
position or dirty
- Nozzle clogged
- Leaks in oil pipes
- Oil pump provides only low pressure
- The photo-electric cell does not receive
sufficient light or is faulty
- Insufficient ventilation
- Safety thermostat in incorrect position
- Faulty safety thermostat
REMEDY
- Check main on/off switch and power line
- Have cable replaced by a qualified
technician
- Turn the termostat to a higher tempe-
rature
- Insert protection cap in thermostat outlet
- Reset safety thermostat
- Fill the oil tank
- Clean or replace the oil filter
- Contact qualified personnel
- Check the pipes and if necessary
replace
- Clean or replace the nozzle
- Consutate qualified personnel
- Clean or replace the nozzle
- Check and if necessary replace oil pipes
- Consult qualified personnel
- Clean the photo-electric cell; if this is not
sufficient consult qualified personnel
- Consult qualified personnel
- Check position of safety thermostat
- Consult qualified personnel
13
Tabla de contenido
loading

Este manual también es adecuado para:

Ka 40Ka 70

Tabla de contenido