5.1. Start-up
For functioning of the appliance
with environment thermostat
(230V), remove the protective
cap from the thermostat outlet
(fig. 1 N°1) and insert the ther-
mostat plug in the outlet. For
functioning without thermostat,
insert the protective cap of the
thermostat outlet in the outlet.
Fill the tank with clean oil.
Insert the power plug in a 230V
~ 50 Hz single-phase, grounded
power outlet.If the greeen light
(fig 1 N°4) is ON, the appliance
is powered.
Grounding is mandatory.
Connect the appliance to any
stack or to a flue to vent fumes
Before performing any main-
tenance operations, always
disconnect the power plug.
Maintenance must be carried
out by qualified personnel
(see also §7).
The equipment must be thor-
oughly cleaned once a year to
12
5. Instructions for use
into the outside air. To obtain a
draught of at least 0.1 mbar in
the flue, the flue path must rise.
Avoid any bends or elbows in
the initial section of pipe for at
least 3 m. If the appliance is
used in a closed environment
without stack, refer to the instal-
lation instructions (§ 4).
Set any environment thermostat
to maximum temperature.
Turn the switch (fig. 1 N°3) to
the "ON" position
Adjust the thermostat to the
required temperature.
5.2. Manual reset
The appliance is complete with a
manual reset button-light (RESET)
6. Maintenance
assure correct combustion and
long life.
Clean periodically:
the oil nozzle and associated
filter;
the tank filter cartridge;
the electrodes, checking dis-
tance of tips;
the vanes of the fan;
(fig 1 N° 2). When the appliance
locks out, the red light of the push-
button (fig. 1 N°2) comes on. In this
case, press the RESET button to
re-start the appliance (see
also"Troubleshooting")
5.3. Shut-down
Turn the switch to the "OFF"
position. The fan continues to
rotate for approx. 3 minutes in
order to cool the chamber and
the appliance shuts down only
when the temperature has
dropped sufficiently.
Never stop the generator by
pulling out the plug.
the inside of the equipment
using compressed air:
the photo-electric cell
Make a periodic inspection of
cables and electrical connec-
tions;
Check the oil filter periodically
and if necessary replace.