Maintenance Instructions - EGAmaster 51660 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

JACK
JACK
WILL
WILL
NOT
NOT
LIFT
HOLD
LOAD
LOAD
X
x
X
X
X
X
X
X
Safe Operating Temperature is between 4°C and 41°C (40°F and 105°F).
If you use and maintain your equipment properly, it will give you many years of service. Follow
the maintenance instructions carefully to keep your equipment in good working condition. Never
perform any maintenance on the equipment while it is under a load.
Inspection
You should inspect the product for damage, wear, broken or missing parts (e.g.: pins) and
that all components function before each use. Follow lubrication and storage instructions for
optimum product performance.
Binding
If the product binds while under a load, use equipment with equal or a larger load capacity to
lower the load safely to the ground. After un-binding; clean, lubricate and test that equipment
is working properly. Rusty components, dirt, or worn parts can be causes of binding Clean and
lubricate the equipment as indicated in the lubrication section. Test the equipment by lifting
without a load. If the binding continues contact Customer Service.
Cleaning
If the moving parts of the equipment are obstructed, use cleaning solvent or another good
degreaser to clean the equipment. Remove any existing rust, with a penetrating lubricant.
12
TROUBLESHOOTING
JACK
WILL NOT
POOR
WILL
JACK
NOT
LIFTING
LOWER
EXTENSION
x
X
X
X

MAINTENANCE INSTRUCTIONS

LIFT TO
CAUSES AND SOLUTIONS
FULL
Release valve is not completely closed
(Turn handle clockwise).
Weight Capacity Exceeded.
X
Low oil level. Add oil as required.
Oil reservoir is overfilled.
X
Lubricate moving parts.
X
Jack is binding or foreign obstruction
Power unit malfunctioning.
Replace the power unit.
Air is in the hydraulics.
Purge air from system.
Drain excessive oil.
Tabla de contenido
loading

Este manual también es adecuado para:

51661

Tabla de contenido