DIPRA SPIDO POMPE BOOSTER Manual De Instrucciones Original página 17

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

extended period of time, it should be emptied
completely in by opening the water drain screw (7).
Subsequently, please flush the pump with clean
water. Then allow the pump body to dry completely
in order to prevent corrosion damage.
Cleaning the coarse filter insert.
Water left in the pump may freeze in case of frost and
thus cause considerable damage. Please store the
pump in a dry, frost- protected place.
In the case of malfunction, you should first of all
check whether it was caused by an operating error
or some other reason which cannot be attributed to
a defect of the device - for instance a power failure.
Malfunction
The pump does not start
The pump does not draw
water
Quick stop and start cycles
Noise or noisy operation
Pump casing leakage
- Check electrical connections: fuse, circuit breaker, main switch or ground
connection.
- Check the supply voltage.
- Check the electrical cable for bending.
- Check diaphragm assembly (seized or locked or frozen)
- Check that the pump is not clogged with debris and that there is water
coming in.
- Check the condition of the inlet hose (clogged, bent, etc.).
- Check the supply voltage.
- Remove debris from pump inlet/outlet valves or from inflated/dry valves.
- Check for cracks in the pump body.
- Check the diameter of the pipe: a valve that is too closed or a pipe that is too
small can restrict the pumping.
- Caused by vibrating pipes.
- Caused by too little water entering (clogged strainer, bent pipe, restrictive
valves).
- Check that the pump is not connected directly to a rigid pipe.
- Check that the pump is mounted on a flat surface.
- Check that there is no air in the pipework.
- Check that all screws are tight.
- Check that the pump diaphragm is not punctured.
The list below shows some possible malfunctions
of the device, possible causes and tips on their
elimination. All the measures referred to may only
be carried out with the pump being separated from
the electrical mains. If you yourself feel unable to
eliminate any of these malfunctions, please contact
the customer service department or your point of
sales. Any repair beyond the scope specified below
must only be performed by qualified staff. Please
bear in mind that all warranty claims will become
void in the case of damage caused by inappropriate
repair attempts, and that we decline any liability for
any ensuing damage.
Solutions
GB
Tabla de contenido
loading

Este manual también es adecuado para:

002730

Tabla de contenido