RIB R50 Manual Del Usuario página 6

Ocultar thumbs Ver también para R50:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
1ST PHASE (Adjustments and checks)
1- With the door at the halfway point if the course, fasten the R50 to the top of the door. R50
wheels must touch the ground.
2- Remove the rubber plug B that frees the spring pressing the wheels to the ground from
the R50 drawbar with an adjustable pressure by tuning the C ring nuts.
3- Close the gates manually, the wheels should position themselves in such a manner as
to follow the motion of the wing door. Block the adjusting nuts from the drawbar slope.
4- Raise the wheels from the ground by using the appropriate R50 lever
5- Position and adjust electric end stops on the gate's column in such a manner as to
assure they are pressed down when moving the door manually into a complete opening and closure position.
6-Place the doors in an intermediary position, and lower the wheels once again.
7 - Set the microswitches DIP 1-2-3-4-5-6-7-12-14-16-17-18 in OFF position and the microswitches
DIP 13-15-19-20 in ON position (in case of an electric lock put microswitches DIP 8-9-10-11 in ON
position too)
8 - Put DIP 1 on ON. The DL1 LED flashes.
9 - Press the PROG button and hold it. The DL2 and DL4 LEDs turn on. M1 must open followed by M2 while PROG
is pressed.
After 3 seconds and up to 10 seconds turn the TORQUE trimmer clockwise to increase force (if necessary).
After 10 seconds Low speed starts. Adjust it via the LOW SPEED trimmer.
10 - Release the PROG button. If necessary, reverse V with W of the motor(s) that close to re-establish
correct movement direction.
11 - Press the PROG button and hold it. The DL5 and DL3 LEDs turn on. M2 must close followed by M1. Keep PROG
pressed until the gate has closed completely.
12 - Put DIP 1 on OFF. The DL1 LED stops flashing
2nd PHASE (Programming total opening time)
ATTENTION: DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND THEIR INTERVENTION STOPS PROGRAMMING
(THE DL1 LED FROM FLASHING REMAINS ON FIXED). TO REPEAT THE PROGRAMMING PROCEDURE POSITION
THE DIP 1 AND DIP 2 TO OFF, CLOSE THE GATE THROUGH PROCEDURE
THE PROGRAMMING OF THE CHOICE.
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG./RADIO/OPEN/START button => M1 opens.
When the opening limit switch LSO M1 is pressed, M1 stops and M2 opens.
When the opening limit switch LSO M2 is pressed. M2 stops.
4 - Press the PROG./RADIO/OPEN/START button => M2 closes.
5 - After a few seconds press the PROG./RADIO/OPEN/START button => M1 closes and determine the phase displacement between M2
and M1.
When the LSC M2 and LSC M1 limit switches are pressed, the motors are switched off.
At the same time the LED DL1 will stop flashing, signaling the exit from the programming procedure.
From this moment the safety devices or other gate commands will work normally (inversions, stops, alarms, etc.).
6 - AT THE END OF PROGRAMMING, RESET THE DIP 2 IN OFF POSITION.
3rd PHASE Programming the remote control
Programming can be done only when the gate is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON. The LED DL12 flashes red for 10 seconds.
2 - Press the remote button (usually channel A) within the allotted 10 seconds. If the remote is memorized
properly LED DL12 blinks green and a buzzer tone confirms the correct memorization. The 10 seconds
for programming the codes are automatically renewed, with LED DL12 which flashes red, in order to
store the next transmitter.
3 - To finish programming, wait 10 seconds, or press the PROG button briefly. LED DL12 stops flashing.
4 - Re-set DIP 1 to OFF and DIP 2 to OFF.
4th PHASE (Programming pedestrian opening times)
The gate must be fully closed.
1 - Turn DIP 2 to ON position, the LED DL1 starts blinking quickly.
2 - Immediately, turn also DIP 1 to ON position, the LED DL1 starts blinking slowly.
3 - Press the pedestrian pushbutton (COM A+/PED.), motor M1 opens
4 - When the motor M1 leaf is opened enough for the pedestrian crossing, press the pedestrian
pushbutton to stop the travel (thus defining the opening stroke of motor M1).
5 - Press the pedestrian pushbutton (COM A+/PED.), M1 closes.
ON
6 - Turn DIP 1 and DIP 2 to OFF position.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
5th PHASE Customising the configuration
ON
The configuration can be modified by moving the various microswitches
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DIP 4
DIP 5
DIP 6
DIP 7
DIP 8
DIP 9
DIP 10
DIP 11
DIP 12
DIP 13
DIP 14
DIP 15
DIP 16
ON
DIP 17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DIP 18 must remain OFF and DIP 19-20 ON for R50 230V
ATTENTION: Install the APP card (or the APP+ card with its modules) and use your smartphone with the RIB GATE App to take
AND REPEAT
Adjustments and checks
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Photocells always active (OFF) - Photocells active only during closing (ON)
Pre-blinking (ON) - Normal blinking (OFF)
Single pulse command (START) and RADIO - step-by-step (ON) - automatic (OFF)
Photocells AUTO-TEST activation (ON-activated).
Electric lock activation (ON-activated)
Electric lock pulse release (ON-activated)
Motors manual release facilitation (ON-activated)
Electric lock pulse engagement (ON-activated)
Selection of 1 or 2 motor operation (default OFF 2 motors)
Activate the radio system SUN/MOON (ON) - SUN-PRO (OFF)
Timed operation (OFF) - Operation with limit switches (ON)
Slowdown (ON - activated)
Contactors management (ON - activated)
Encoder management (ON - activated)
advantage of all the advanced features that the B2 control board can offer you.
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
loading

Este manual también es adecuado para:

B2-crx