Idiomas disponibles

Figure 18. Untangle the Floating cable
5.
Loosely coil the power cable starting at the
cleaner and moving toward the connection
point at control box. Store the cable by
wrapping it around the hook located on the
front of the caddy.

Replacing Wear Parts

Replacing Brushes
The cleaner is fitted with PVC brushes with a
"wear" indicator (Figure 19).
Figure 19. Worn Brush Indicator
To maintain cleaner performance at its best you
need to replace the brushes as soon as one of the
wear indicators is reached (even if the blade wear
is not even). It is recommended that you replace
the brushes when the rubber is worn down to
the top of the wear indicator (or every two years,
whichever comes first).
To replace a worn brush:
1.
Lift the cleaner to a vertical position so that
the handle is up (Figure 20).
Figure 20. Cleaner in Upright Position
2.
Figure 21. Undo the Tabs of the Brush
raised groove
3.
becomes partially
flattened, indicating
excessive wear
Figure 22. Install the New Brush
4.
1
Separate the edges of the brush and undo
the tabs (Figure 21). Remove the worn
brushes.
2
To install the new brush, position the new
brush on the roller with the cleaning blades
facing away from the roller (Figure 22).
3
Thread each tab into the slot provided and
gently feed it through until the heel comes
out at the other side of the slot (Figure 23).