status of the appliance. They are not
intended to be used in other applications
and are not suitable for household room
illumination.
2.6 Disposal
WARNING!
Risk of injury or suffocation.
3. INSTALLATION
WARNING!
Refer to Safety chapters.
3.1 Before the installation
Before you install the hob, write down the
information below from the rating plate. The
rating plate is on the bottom of the hob.
Serial number ...........................
3.2 Built-in hobs
Only use the built-in hobs after you assemble
the hob into correct built-in units and work
surfaces that align to the standards.
3.3 Connection cable
• The hob is supplied with a connection
cable.
• To replace the damaged mains cable, use
the cable type: H05V2V2-F which
withstands a temperature of 90 °C or
higher. The single wire must have a
diameter of minimum 1,5 mm². Speak to
your local Service Centre. The connection
N
L
220-240 V~
• Contact your municipal authority for
information on how to dispose of the
appliance.
• Disconnect the appliance from the mains
supply.
• Cut off the mains electrical cable close to
the appliance and dispose of it.
cable may only be replaced by a qualified
electrician.
WARNING!
All electrical connections must
be made by a qualified
electrician.
CAUTION!
Do not drill or solder the wire
ends. It is forbidden.
CAUTION!
Do not connect the cable without
cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove an insulation of the brown and
black cable ends.
3. Apply a new wire end sleeve of 1.5 mm²
on common cable end (special tool
required).
Cable cross section 1,5 mm²
400V 2~N
N
L1
L2
ENGLISH
59