Specifications - Kärcher WPC 600 SW Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
LED
Display
glows
Spannungsausfall
Uhr stellen !
Power failure
Set clock !
Arret secteur
L'horloge placer
mancan. corrente
regoli l'orolog.
Interruptions in the advance pressure unit
are indicated through red LED at the control
unit of the advance pressure pump.
LED glows
Possible cause
Red LED
Raw water supply has been interrupted
glows
Ambient temperature
Storage temperature, min.
Humidity, max.
Supply voltage, plant
Control media/ active carbon filter
Dosing module
Electrical fuses
Electrical connection value
Raw water temperature
Inlet pressure of raw water
Output range
Drinking water output, max.
Dimensions (h x b x d)
WPC 600 SW
WPC 600 SW-A
WPC 600 SW-AM
Weight in delivered state (without filter fillings)
WPC 600 SW
WPC 600 SW-A
WPC 600 SW-AM
Design base for salt content in raw water (at 15 °C)
Maximum salt content in raw water
18
English
Possible cause
Power failure during operations
Interruptions in the advance pressure unit

Specifications

Remedy
Check power supply; set clock
Remedy
Check raw water supply and restart it
After removing the fault, press the "Reset" key
°C
+1...+60
°C
–10...+70
% rel.
100
V/Hz
400/3~50Hz
V/Hz
prim.: 230/1~50,
sec.: 12/1~50
V/Hz
230/1~50/60
A
25
kW
°C
+2...+40
MPa
0,2...0,6
l/day
15000±15%
l/h
650
mm
1800 x 900 x 800
mm
1800 x 1200 x 800
mm
1800 x 1200 x 800
kg
220
kg
240
kg
260
ppm
35000
ppm
60000
6