control. This will provide the best thermal comfort. Place any object that could impede air
circulation (furniture, armchairs) 50 cm from the front of the appliance. The product must
not be placed in front of or directly below a fixed socket. The bottom of the control panel
must be at least 15cm from the wall or ceiling and 60cm from the floor.
For any prodcut, if the power supply cable is damaged, it must be replaced with a specific
cable. The replacement of the cable must be carried out by ROINTE, our after-sales service
or qualified personnel. The technical characteristics of your product are indicated on the
technical characteristics label.
This product complies with CLASS II safety standards (double insulation). It can be installed
in Zones 2 and 3, positions A and B provided that the following rules are observed:
·
In bathrooms, the product must never be installed in such a way that the control panel
can be reached by a person in the bath or shower. The control panel must be located at a
minimum distance of 1000 mm from any wet areas. The body of the product can be placed
in Zone 2 if the control panel is located within Zone 3.
The weight of some of the products may be heavy. The installation may
require two people.
Please follow these instructions carefully.
MILANO DOWNFLOW ELECTRIC TOWEL RAIL WITH FAN
EN
33