2.5.
Sealing inspection
Open the pressure-reducing valve or natural gas valve and control by
application of much foamy water on the connection to find out any gas
leakage.
Never control by flame.
2.6.
Final inspection
1.
Plug the power cable into the socket and activate the fuse of the
equipment.
2.
Control the functions.
2.6.1.
LPG-NG / NG-LPG conversion
Figure 12
Figure 12.4
Figure 12.2
Figure 12.1
Remove the burner cover and burner as shown in in the Figure
12.
Remove the injector by help of 7's socket screwdriver as
shown in the Figure 12.1
Fix the injector (D) to be converted as shown in the Figure
12.2.
(see table 1).
Replace the burner as shown in the Figure 12.3.
Turn on the burners respectively after conversion and
remove the button on the control panel and set the flame
length by tightening or loosening the screw on the gas
valve (12.4 cock) or in the valve shaft
Figure 12.3
.
EN
11