Press
to cancel the operation and auto switch to
the next setting.
In WEEKLY timer setting, the weekdays are able to be
switched over by pressing
the weekday timer activation and move on to the next
weekday. Press
to cancel the activation of the
weekday and move on to the next setting.
The Schedule Timer setting will terminate if there's no
operation for 5 seconds or
Parameter Setting
Press
in daily display for 5 seconds to enter System
Parameter Setting screen. Repeat the operation to
enter Module Parameter Setting screen. The
will appear while the function is activated.
In System Parameter Setting, the parameters will be
displayed in hour display area (Area 1) in sequence by
pressing
.
In Module Parameter Setting, the modules can be
switched over by pressing
Press
or
to set the value and press
save the value. The setting will terminate if there's no
operation for 5 seconds or
Fault Diagnosis
and
for 5 seconds to enter Fault
Press
Diagnosis. The
icon will appear while the function
is activated.
The fault codes will be displayed in temperature display
area (Area 3) with time recorded. The serial number of
the module will be displayed as 10-bit of Area 4.
Press
and
for more fault information. A
maximum of 16 faults can be recorded.
The setting will terminate if there's no operation for 5
seconds or
is pressed.
Running Status
Press
and
for 5 seconds to enter Running Status
viewing screen. The digital and analog inputs and outputs
are displayed in sequence in hour display area (Area 1) by
pressing
and
.
The modules can be switched over by pressing
Fault Reset
Press
and
for 5 seconds to reset the faults
manually.
PMML0297 rev.0 – 08/2018
6
. Press
to confirm
is pressed.
icon
.
to
is pressed.
.
Keylock
Press
and
for 5 seconds to enter Keylock function.
The
icon will appear and all touch-keys and the physical
button will be disabled while the function is activated.
Press
and
again to terminate the function.
Pump Circulation
Press
for 5 seconds in daily display to enter Pump
Circulation function. The
will operate with no compressor running while this function
is activated.
Low Sound Mode
Press
key for 5 seconds in temperature setting display
to enable Low Sound Mode. Press
seconds in temperature setting display to enable Night Low
Sound Mode. In Night Low Sound Mode the low sound
function will only be activated during 21:00 to 6:00.
Manual Defrost
Press
and
for 5 seconds in temperature setting
display to enter Manual Defrost setting. The modules can
be selected by pressing
pressing
.
Press
to terminate this setting.
icon will appear. The pump
and
for 5
and defrost will begin once by
EN