Infiniton VT-132M Instrucciones De Instalación página 10

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

(C) FOR CONTROL OF FAN FROM WALL
SUPPLY CIRCUIT
BLACK
WHITE
FAN
SWITCH
BLUE OR RED
BLACK FAN
LIGHT LEAD
LEAD
MOTOR
BLUE OR RED
BLUE OR RED
LIGHT
REPAIR GUIDE:
TROUBLE
Fan will not start.
Fan sounds noisy.
Mechanical noise.
Fan wobbles.
08
GROUNDED CONDUCTOR
WIRING BOX
GREEN GROUNDING LEAD
WHITE
(COMMON)
WHITE
WHITE
PROBLEM CAUSE
• Fuse or circuit breaker blown.
• Loose power lone connections
to the fan.
• Speed controler not in correct
position.
• Top canopy touching ceiling.
• Loose fan blades screws.
• Ceiling fan not secured
against ceiling.
• Incorrect speed controller.
• Fan blades are not horizontal
to ceiling.
• Blade screws are loose.
(D) FOR CONTROL OF FAN AND LIGHT FROM WALL
SUPPLY CIRCUIT
BLACK
WHITE
LIGHT
FAN
SWITCH
SWITCH
BLUE OR RED
BLACK FAN
LIGHT LEAD
LEAD
MOTOR
BLUE OR RED
BLUE OR RED
LIGHT
SUGGEST REMEDY
• Check main and branch circuit fuses or circuit
breakers.
• Check line wire connections to fan.
• Check speed controller's position.
• Lower canopy from ceiling to ensure mínimum
3mm clearance.
• Re-tighten all screws on fan blades but never
o ver-tighten.
• Re-tighten all screws in the hanging bracket
or plate.
• Change the controller to the one supplied.
Allow at least for 8 hours setting-in period.
• Measure from ceiling to tips of blades, the
rotate fan so all blades are checked for equal
height from ceiling(not ajustments may be
made by slight pressure up or down on blade
holders).
• Make sure all screws are securely fastened.
GROUNDED CONDUCTOR
WIRING BOX
GREEN GROUNDING LEAD
WHITE
(COMMON)
WHITE
WHITE