PARAMETERS
Heat input
Nominal heat output
Reduced heat output
CO concentration at nominal reference (10% O
CO concentration at reduced reference (10% O
Nominal efficiency
Reduced efficiency
Pellet consumption (max-min)
Heated surface
Flue gas flow rate (min-max)
Draft (min-max)
Flue gas temperature (min-max)
Boiler water
Sanitary water capacity (where present)
Maximum working pressure
Tank capacity
Smoke outlet tube
Diameter air intake
Connecting heating
Connecting sanitary water (where present)
Nominal voltage
Nominal frequency
Power consumption max
Power consumption at rated power*
Power consumption at minimum power*
Power consumption in standby
Water pressure (at 10 k)
Water pressure (at 20 k)
Autonomy of combustion (min - max)
Minimum temperature to return
Noisiness (according to EN 15036-1)
Boiler class
Boiler weight
Operation with respect to the smoke exhaust
Boiler type
Energy class
IEE
Operation range
Stars environmental decree - DM186/2017
Dusts at 13% O2 Ref. Nominal thermal power
N° Test Report
* Circulator included.
44
UNIT
OF MEASUR.
kW
kW
kW
)
mg/m
3
2
)
mg/m
3
2
%
%
kg/h
mc
kg/s
Pa/mbar
°C
litri
litri/minuto
Bar
kg/litri
mm
mm
Inch
Inch
V
Hz
W
W
W
W
mbar
mbar
h
°C
dB
Kg
°C
mg/m
3
MOD. J20
20
18,8
5,3
23
218
94
88
4,2 - 1,3
490
0,0053-0,011
3-8 / 0,03-0,08
61-94
100
14
3
100 - 154
100
50
3/4
1/2
230
50
350
75
55
3,1
306
77
22-74
55
42
5
310
Depression
Non condensing
A+
116
65-80
4
K30422021Z1
MOD. J25
24,3
22,8
5,9
18
217
93,7
91
5,1 - 1,3
610
0,0052-0,0132
3-8 / 0,03-0,08
60-87
100
14
3
100 - 154
100
50
3/4
1/2
230
50
350
88
60
3,1
567
142
20-74
55
42
5
310
119
65-80
6
K30422021Z1