Troubleshooting; Technical Data; Product Specifications In Accordance With Regulation (Eu) 2019 / 1782 Power Supplies - Profi Care PC-AKS 3102 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
• Life of the rechargeable battery: Even when switched
off, the rechargeable battery discharges continuously.
If the appliance is out of use for a longer period of time,
Problem
The appliance is without function. The rechargeable battery is
During operation, the LED on
the switch flashes for approx.
30 seconds. The appliance then
switches off.
Weak suction power.
The battery rechargeable does
not hold a charge.

Technical Data

Model:............................................................... PC-AKS 3102
Net weight (Handheld unit,
charging station, power supply unit): ............. approx. 0.83 kg
Protection class (appliance): ...............................................
Protection class (power supply unit): ...................................
Rechargeable Battery: .................3 × 3.7 V, 2000 mAh Li-Ion
Operating time:..................................... 30 minutes maximum
Charging time: .............................................approx. 4.5 hours
The right to make technical and design modifications in
the course of continuous product development remains
reserved.
This appliance has been tested according to all applicable,
current CE directives and built according to the latest safety
regulations.
Product Specifications in Accordance with
Regulation (EU) 2019 / 1782 Power Supplies
Information about
the power supply used
Clatronic International GmbH
Commercial register number
HRB 9158
Industriering Ost 40,
47906 Kempen
Germany
12
PC-AKS3102_IM

Troubleshooting

Possible Cause
empty.
The rechargeable battery is
defect.
The rechargeable battery is
empty.
The battery is almost empty.
The dust container is full.
The filters are dirty.
The rechargeable battery has
reached the end of its life.
Information about
the power supply used
Model identifier
Input voltage
Input alternating current frequency
Output voltage AC / DC
Output current
Output power
Average efficiency in operation
Low load efficiency (10 %)
No-load power consumption
* not applicable due to an output power of less than 10 W.
The relevant load conditions are as follows:
Percentage of nameplate output current
Load condition 1
Load condition 2
Value
Unit
Load condition 3
Load condition 4
Load condition 5
Load condition 6
charge the rechargeable battery at least once every
4 to 6 weeks.
Remedy
Charge the rechargeable battery.
Contact our service or your dealer.
Charge the rechargeable battery.
Charge the rechargeable battery.
Empty the dust container.
Clean the filters as described under "Maintenance".
CAUTION:
Only resume operation with dry filters!
Contact our service or your dealer.
Value
Unit
SEU007A-140050
100 – 240 V~
50 – 60 Hz
14.0 V DC
0.5 A
7.0 W
79.9 %
* %
0.06 W
100 % ± 2 %
75 % ± 2 %
50 % ± 2 %
25 % ± 2 %
10 % ± 1 %
0 % (no-load condition)
29.12.21
Tabla de contenido

Solución de problemas

loading

Tabla de contenido