Handook page
36/128
Installation Guide
H/U952T Terminal Transmitter
3.6
3.7
3.8
2002-11-13/ Rev. A
Connection of Supply Voltage
• Connect supply voltage to connector J102 screw 1 and 2. See also the System
Installation document, under Power Supply.
Supply voltage-in
Supply voltage-out
Figure 10. Power supply connector.
Coax Connection to Antenna
• Connect the antenna coax to the antenna output connector located at the upper right
of the transmitter, see
• To prevent water from running along the antenna cable and entering the transmitter,
let the cable form a loop downwards. See
Transmitter
Figure 11. Preventing water to run along the cable and entering the transmitter.
For assembly of the coax connector to the cable, see
Connection to Slave Transmitter
If the transmitter is to drive a slave transmitter, slave driver U952DR (UHF systems) or
power divider MPT-50 (HF systems) is to be installed between the transmitter and the
slave. The slave driver or power divider is connected to the antenna output, in series with
the coax from the antenna.
H/U952T
J102
1
+12V
2
GND
3
+12V
4
GND
figure 1
on page 1.
figure 11
TD 92022GB
below.
Appendix
B.
7