Kohler K-6350 Guia De Instalacion página 7

Ocultar thumbs Ver también para K-6350:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Mounting
Nut
6. Adjust the Temperature Setting
NOTE
Prior to adjustment, make sure the handle is in the
:
maximum hot position.
- Remove the setscrew, handle, and bonnet. Turn on the water to the
maximum temperature by pushing the valve stem up, and turning it
clockwise.
- Mark the current position of the temperature stop tab (top edge) on
the mounting nut with a marker or pencil. Lift the indexer and top
disc just enough to clear the valve splines and to allow rotation.
NOTE
Each spline notch is an average 9.5_F (5.3_C) change in
:
temperature.
- Turn the indexer, top disc, and valve stem counterclockwise until the
desired temperature is achieved. When desired temperature is
achieved, reinstall the indexer and top disc to the valve, making sure
the top disc is snapped fully into the indexer.
- Turn off the water by pulling the valve stem down. Reinstall the
bonnet, handle, and setscrew.
Kohler Co.
Bonnet
Stop
Valve Stem
Tab
7
Handle
Setscrew
Top Disc
Indexer
Splines
A
1025490-2-
Tabla de contenido
loading

Tabla de contenido