Technical data 
 
Parameter 
value 
Name of the product 
Model 
Supply voltage [V~] / Power 
supply frequency [Hz] 
Rated current (of power 
supply) 
Number and type of batteries 
Resolution 
Temperature measurement 
range [°C] 
Temperature measurement 
accuracy [°C] 
Humidity measurement range 
[%] 
Humidity measurement 
accuracy [%] 
CO
concentration 
measurement range [ppm] 
CO
concentration 
measurement accuracy 
Feedback time (t90) [min] 
Measurement sampling 
frequency [s] 
Protection class 
Ambient temperature [°C] / 
Humidity [%] during operation 
Dimensions [Width x Depth x 
Height; mm] 
Weight [kg] 
*
Carbon dioxide concentration values in other ranges are values used as reference. 
** At temperature exceeding the 0÷50°C range the device stops performing CO
concentration measurement. The measurement is performed again when the 
temperature returns to the 2÷48°C range. 
Parameter 
value 
Thermo hygrometer with carbon dioxide 
SBS‐CO‐100 
230/50  
0.35  
3 x AAA 1.5V  
Temperature: 0.1 °C 
Humidity: 0.1 % 
CO
: 1ppm  
‐30 ÷ 65 (internal probe) 
‐40 ÷ 125 (external probe)  
±0.3 (for ‐10÷65°C) 
±0.5 (other values)  
 
0 ÷ 100 (without condensation) 
±3 (for 10 ÷ 90 %, at 25°C) 
±4 (other values)  
0 ÷ 10000**  
±3%±40ppm (for 400 ÷ 2000ppm)* 
15  
5  
II  
‐30 ÷ 65 / 0 ÷ 100 *** 
105x95x20  
0.1  
 
2
Tabla de contenido