5. CONNECTION
5.1. Power supply
The equipment has a 100-240VAC power input which allows the connection of the
equipment to the mains by means of the supplied cable, and if required by safety
standards, a secondary power supply input of 24 VDC.
5.2. Output zones connection
5.2.1. Speakers line connection without surveillance
IF-704ETH version 5.0.001
IF-704ETH
PRIMARY
POWER SUPPLY
24VDC
POWER SUPPLY
I924UP (not included)
ZONE 1
INPUT
AMPLIFIER
ZONA 2
INPUT
AMPLIFIER
LINE OUTPUT
SECONDARY
POWER SUPPLY
RJ45 OUTPUT "A" and OUTPUT "B" CONNECTORS PINOUT
Pin 1: AUDIO H output (HOT)
Pin 2: AUDIO C output (COLD)
Pin 3: +24 VDC input to monitoring the amplifier.
Pin 4: Not used.
Pin 5: Not used.
Pin 6: PRIORITY output contact.
Pin 7: Not used.
Pin 8:
Metal Shield:
SPEAKERS
LINE OUTPUT
ZONE 2 SPEAKERS LINE
SPEAKERS
R+D Department
IP Audio interface
with 4 outputs
Internal jumper
JP3/JP1
GND
Internal jumper
JP5/JP6
ZONE 1 SPEAKERS LINE
9