CONSTRUCT RECESS
Study the roughing-in diagrams on Page 3.
Construct a recess with a header that is square vertically
and horizontally in accordance with the roughing-in
dimensions. Do not nail the header with 2x2 brace to
the stud frame until after the module is positioned in
the recess. If desired, install a 2x2 brace around the
recess opening.
If extra grab bars are specified: Provide 2x6 bridging or
attachment at specified positions. Refer to the grab bar
manufacturer's instructions.
Cut a 5" (12.7cm) diameter hole in the floor at the drain
location.
SEPARATE THE MODULE
Multi-piece modules are shipped assembled and must be
separated for transportation into the installation area and
application of sealant.
Protect the module joining surfaces by covering the floor
or other level surface with a cloth or soft padding before
setting module sections down.
Lay the module face down on the protected surface.
Loosen and remove all nuts and washers. Keep all
fasteners for reassembly.
Slide the alignment clips above the section joint, but do not
remove clips completely. Remove the split washers that
act as spacers during shipping.
Remove the bolts and separate the module into sections.
JOIN AND SEAL THE MODULE SECTIONS
Carefully move sections to the installation area, setting
them again on a prepared, level surface (this is a two-man
job). Move the lowest module section into re-assembly
area first.
Re-assemble sections by placing upper sections over
lower sections. Align sections by sliding the alignment clip
over the alignment strip of each block. Start at each door
column, then the back corners, then back wall, then
sidewalls.
Replace bolts in the mounting blocks with a flat washer
under the bolt head. Install flat washer, split washer and
start a nut on each bolt, but do not tighten. Do not put the
bolts in place at the door columns and back corners at this
time.
B
1011310-2-
84"
(213.4cm)
6" (15.2cm)
Typ.
63"
(160cm)
20-1/2"
(52.1cm)
22-5/8"
45-1/4"
(57.5cm)
(114.9cm)
Shipping
Assembly
Flat
Washer
Split
Washer
Nut
4
Nail Header
2x2
With 2x2 Brace
Braces
to Framing
After Setting
the Module In
the Recess
38" (96.5cm)
29-3/8"
(74.6cm)
Fig. #3
Split
Washer
Remove Split
Washer
Fig. #4
Fig. #5
Kohler Co.
Tabla de contenido
loading

Este manual también es adecuado para:

Freewill k-12201Freewill k-12207Freewill k-12208