Operational start-up
• Check that the pump is standing
firmly on the bottom of the shaft
or hung up safely.
• Check whether the pressure line
has been attached correctly and
the unused pump outlet is fully
closed.
• Avoid that the pump runs dry.
Regularly check the function
of the float switch. In case of
non-observance or if the pump
runs dry, guarantee and liability
claims are invalidated.
• Check that the electrical con-
nection is 230 V ~50 Hz
• Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
ficiently fused (at least 6 A, RCD
switch). Insert the pump plug
into the plug socket and the
pump is ready for operation.
• Make sure that moisture or wa-
ter never come in contact with
the mains connection. There is
a risk of electrocution.
Cleaning/Maintenance/
Storage
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to carry out
any work that is not described in
these instructions. Use only origi-
nal parts.
This will prevent damage to the
equipment and any resulting per-
sonal injury.
Pull out the power plug before eve-
ry maintenance operation. There
is a risk of electrocution or of injury
from moving parts.
General cleaning instructions
•
In case of transport for utilization in
different locations, the pump must be
cleaned with clear water after every
use.
•
In case of stationary installation, the
function of the float switch (
to be checked regularly (at the latest
every three months).
•
With a water jet, remove fluff and
fibrous particles which are possibly
present in the pump casing
•
Regularly remove sludge from the pit
base (at the latest every 3 months)
and also clean the shaft walls
•
Clean precipitation from the float
switch with clear water,
•
In the case of a long period of non-
use, the pump must be thoroughly
cleaned after the last use and before
the new use, since difficulties in start-
up can arise due to precipitation and
residues.
Cleaning the Fan Wheel
In case of soiling or blockage of the impel-
ler, this can be cleaned via the pump out-
let (3) or by removing the floor plate (4):
1. Unscrew the bracket adapter
(
10) from the pump outlet
(
3).
2. Remove the 3 screws on the
bottom of the base (5) and take
off the base plate (4).
3. Clean the fan wheel using clean
water.
GB