a safe and secure location that will not be accessible to
individuals without proper PPE, loosely cover, and allow
it to stand at least 24 hours . Dispose of the waste
container in accordance with federal, state, and
local regulations .
2.7.2 "B" Chemical, POLYOL
If the "B" chemical spills from the tank, hose, or
Insta-Flo
Gun, wear all PPE, dike and isolate the spill
area . Keep unnecessary and unprotected personnel
from entering the area . Soak up the residue from the
surface with soap and water . Discard in accordance with
federal, state, and local regulations .

2.8 Cautions

2.8.1 Storage Temperature

Recommended storage temperature:
60°–80°F (16°–27°C) . Storage below 60°F (16°C) is not
recommended . Do not store at temperatures above
120°F (49°C) .

2.8.2 Building Codes

In many areas, building codes may restrict the use
of cellular plastics or polyurethane foam in exposed,
interior finishing material applications . Under certain
application code, the use of these materials may be
prohibited . The foam produced by this product is organic
and may constitute a fire hazard if improperly applied .
Consult local building codes .
When air sealing buildings, ensure that combustion
appliances, such as furnaces, water heaters, wood burn-
ing stoves, gas stoves and gas dryers are properly vented
to the outside . See website: http://www . e pa . g ov/iaq/
homes/hip-ventilation .html . In Canada visit:
http://archive .nrc-cnrc . g c . c a/eng/ibp/irc/bsi/83-house-
ventilation .html .

2.8.3 Surface Temperature Restrictions

Polyurethane foam should not be used in direct contact
with chimneys, heat vents, steam pipes, or other surface
areas that exceed 240°F (116°C) . The foam should not be
left exposed or inadequately protected for both interior
and exterior finishing materials . It is strongly recom-
mended in all applications that the foam be protected
by approved facings and coatings .
2.8.4 Open Flame / Spark Source
Do not smoke or operate the system in close proximity
to an open flame or spark source . Ensure pilot lights
8
are off . Welding on or near cured polyurethane foam
requires special precautions . Consult DuPont for
instructions .

2.8.5 Excessive Foam Dispensing

Do not apply excessive thicknesses at one time as this
may result in spontaneous combustion . For thickness
greater than two inches of cured foam, dispense foam
in multiple layers, allowing the heat from foaming to
dissipate between sprayings .

2.8.6 Isocyanate Contamination

Isocyanate and water do not mix, and this can happen
even from the water in the air . The material will solidify
and then the gun and hose will be unusable . The best
thing to do is to take care of the guns and hoses by
using the entire kit within 30 days of opening .
WARNING: Water reacts aggressively with isocyanate
("A" chemical/ISO) . Reactions within a confined space
such as within a hose may present a safety concern .
Even small amounts of water vapor may cause a block-
age or an adverse reaction . Water carried within the
polyol ("B" chemical/POLY) hose to the point where
blending with isocyanate occurs must be avoided .

2.8.7 Confined Space

When preparing a site for spray foam, all considerations
for potential confined spaces must be taken and all
OSHA requirements must be met if applicable .

2.9 Training

DuPont does not recommend use of Froth-Pak
Insulation and Sealant Kits without having completed the
OSHA/CCOHS requirements for respiratory protection (i . e .
routine health exams and fit testing, cartridge change out
schedule, required OSHA/CCOHS documentation), having
completed review of the instructions herein, and having
reviewed the Safe Use and Handling presentations available
at: https://www . d upont . c om/building/safe-handling .html
or frothpak . c om
DuPont recommends additional training provided by:
– Spray Polyurethane Foam Alliance
http://www . f rothpak . c om
– (CPI) of the AmericanChemistry Council
http://polyurethane .americanchemistry . c om/About-CPI
For hands on training information contact:
DuPont at: www . f rothpak . c om 1-866-583-2583
(technical support) 1-833-989-0132 (sales information)