I N S T R U C T I O N S
Type MSD4-1999-UA
67118C 08/13 - (LOA)
• English
• Español
English
CS4
THERMOSTAT
TM
A wireless, radio controlled thermostat recom-
mended for Comfort System 4. The thermostat
is ideal for all floor types and controls the
heating on the basis of room, floor or room/floor
limit temperature. Wireless communication to
the central controller ensures easy installation.
The thermostat is for flush mounting in a wall
socket. A baseplate for external wall mounting
is available.
PRODUCT PROgRAMME
MSD4-1999-UA Radio controlled thermostat
with built-in room sensor and
floor sensor
WARNINg – Important Safety Instructions
Disconnect the power supply before carrying
out any installation or maintenance work on this
unit and associated components. This unit and
associated components should only be installed
by a competent person (i.e. a qualified electri-
cian). Electrical installation must be in accord-
ance with appropriate statutory regulations.
MOUNTINg Of SENSOR
The floor sensor contains a safety extra-low
voltage (SELV) circuit, allowing it to be placed
as close to the floor surface as possible without
having to take account of the risk of shock
should the sensor cable become damaged.
The two wires connecting the sensor to the
mounting box must be additionally insulated,
e.g. shrink flex.
To prevent loose wires in the fixed installation
from coming into contact with the terminal
block for the floor sensor, they must be re-
strained using cable ties.
It is recommended that the cable and sensor be
placed in a non-conductive installation pipe em-
bedded in the floor (fig. 3). The end of the pipe
must be sealed and the pipe placed as high as
possible in the concrete layer. Alternatively, the
sensor can be embedded directly in the floor.
The sensor cable must be led through a sepa-
rate pipe or segregated from power cables.
The floor sensor must be centred between
loops of heating cable.
GREEN COMFORT
Máximo conforto com reduzido consumo de energia
All manuals and user guides at all-guides.com
The sensor cable may be extended up to 100
m by means of a separate two-core cable. Two
vacant wires in a multi-core cable used, for
example, to supply current to the floor heating
cable must not be used. The switching peaks of
such current supply lines may create interfer-
ence signals that prevent optimum controller
function. If a shielded cable is used, the shield
must not be connected to earth (PE). The two-
core cable must be placed in a separate pipe or
segregated from power cables.
MOUNTINg Of THERMOSTAT
WITH bUIlT-IN SENSOR
The room sensor is used for comfort tempera-
ture regulation in rooms. The thermostat should
be mounted on the wall approx. 1.6 m above
the floor in such a way as to allow free air
circulation around it. The thermostat must never
be covered by a curtain or similar. Observe the
minimum distance from large metal surfaces,
electronic equipment, electric motors, etc.
(fig. 4a). To ensure good transmission, the unit
should be placed as high as possible, min. 50
cm above the floor (fig. 4b). Draughts and direct
sunlight or other heat sources must be avoided
(fig. 4).
Mounting of thermostat
1. Slide the power button down to Off "0".
2. Release the front cover ONLY by inserting a
small screwdriver into the hole on either side
of the thermostat.
3. Connect the wires in accordance with the
diagram (fig. 2).
4. Mount the thermostat in the wall socket.
Please ensure that the adapter plate is
properly clipped on the thermostat.
5. Fit the frame and carefully press the cover
onto the thermostat. Ensure that both the
power slide button on the cover and the
power switch pin are down.
DO NOT open the thermostat by releasing the
four fixing clips on the back.
SETUP
See user manual for Comfort System 4 - Central
Controller.
Quick guide to thermostat setup:
1.
Activate the Master by
pressing the Menu button
and selecting System
settings.
2.
Select Add to unit.
3. Activate the thermostat to
be set up. The thermostat
will display its address.
4. Select zone/name.
fAUlT lOCATION
If the sensor is disconnected or short-circuited,
the heating system is switched off. The sensor
can be checked against the resistance table
(fig. 5).
© 2013 OJ Electronics A/S
ERROR CODES
E0: Internal error. The thermostat must be
replaced.
E1: Built-in sensor short-circuited or
disconnected.
E2: External sensor short-circuited or
disconnected.
E5: Internal overheating. Inspect the installation.
CE MARkINg
According to the following directives:
LVD 2006/95/EC, EMC 2004/108/EC,
R&TTE 1999/5/EC.
ClASSIfICATION
The product is a Class II device (enhanced insula-
tion) and must be connected in the following way:
Term. 1:
Neutral (N)
Term. 2:
Phase (L) 230 V ±10 %, 50/60 Hz
Term. 3-4:
Load, max. 16 A / 3600 W
Term. X:
Do not connect
Term. 5-6:
External floor sensor
ENvIRONMENT AND RECyClINg
Please help us to protect the environment by
disposing of the packaging in accordance with
national regulations for waste processing.
RECyClINg Of ObSOlETE APPlIANCES
Appliances with this label must not be
disposed of with general household
waste. They must be collected
separately and disposed of in
compliance with local regulations.
TECHNICAl DATA
Voltage .......................... 230 V AC ±10 % 50 Hz
Max. pre-fuse .............................................. 16 A
Built-in circuit breaker .................... 2-pole, 16 A
Output relay ............. Make contact - SPST - NO
Output .................................... Max. 16 A / 3600
Control principle .................................... PWM/PI
Stand-by power ........................................... 1 W
RF frequency band .............................868.3 Mhz
RF transmission range ......100 metres/open field
Temperature range ............................. +5/+40 °C
Limit sensor ....................................... +5/+40 °C
Ambient operating temperature .......... +0/+25 °C
Sensor input type ....................................... SELV
Pollution degree ................................................ 2
Overvoltage ............................................... Cat. II
Rated impulse voltage ................................. 4 kV
Systemsettings
Enclosure rating ........................................ IP 21*
Dimensions .................... H/115, W/84, D/40 mm
Mounting depth ....................................... 20 mm
Display ........................ H/25, W48 mm, segment
EU Registered Design ........ 001534462-0001/2
Add to unit
According to EN 60730-1:2011
Automatic action type 1
* IP 21 applies only to front with cover after
mounting in a flush box
The thermostat is maintenance free.
OJ ElECTRONICS A/S
Stenager 13B · DK-6400 Sønderborg
Tel: +45 73 12 13 14 · Fax: +45 73 12 13 13
1