Specifications
Operating Conditions:
Temperature: 0 ºC to 50 ºC (32 ºF to 122 ºF)
Relative Humidity (non-condensing): 80% maximum for temperatures up to 31 ºC
(88 ºF), decreasing linearly to 50% maximum at 49 ºC (120 ºF)
Indoor use only
Altitude: 2000 m (6500 ft) maximum
Pollution Degree: 2
Storage Conditions (remove batteries):
Temperature: -29 ºC to 60 ºC (-20 ºF to 140 ºF)
Relative Humidity (non-condensing): 0% to 70%
Measurement Category: Cat III, 750 V per IEC 61010-1
Transmitter Operating Voltage: 0 to 750 volts, AC/DC
Transmitter Operating Frequency: 15.15 kHz
Tracing Range:
Live Line Mode: Up to 6 m (20 ft) from circuit
Open Line Mode: Up to 3 m (10 ft) with a metallic connection to ground;
0.3 to 0.9 m (1 to 3 ft) with a capacitive ground reference
Auto Power Off Intervals:
Transmitter: 4 hours
Receiver: 30 minutes without signal
Receiver LCD: 2 minutes without signal, automatically turns on when signal is recaptured
Power Supply:
Transmitter: Two 1.5 V AA batteries
Receiver: Two 1.5 V AA batteries

Measurement Categories

These definitions were derived from the international safety standard for insulation coordination
as it applies to measurement, control, and laboratory equipment. These measurement categories
are explained in more detail by the International Electrotechnical Commission; refer to either of
their publications: IEC 61010-1 or IEC 60664.
Measurement Category III
Distribution level. Permanently installed machines and the circuits they are hard-wired to. Some
examples include conveyor systems and the main circuit breaker panels of a building's electrical
system.
Measurement Category IV
Primary supply level. Overhead lines and other cable systems. Some examples include cables,
meters, transformers, and other exterior equipment owned by the power utility.

Statement of Conformity

Greenlee Textron Inc. is certified in accordance with ISO 9001 (2000) for our Quality Management
Systems.
The instrument enclosed has been checked and/or calibrated using equipment that is traceable
to the National Institute for Standards and Technology (NIST).
CS-8000