Fein GRIT GXE Manual De Instrucciones página 13

Ocultar thumbs Ver también para GRIT GXE:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
Mount the safety cover (14) and tighten the four screws
(15) again.
Switch the machine on and check the true running.
In the case of strong vibrations or noise, there
may be an imbalance on the brush or on the
grinding or polishing tool. Replace out-of-bal-
ance application tools immediately! Pay attention
to the correct rotation direction of the applica-
tion tools!
Adjust the grinding rest (6) to the required height.
Adjust the required gap clearance with the handle
screw (8).
Operating instructions.
Switching on:
Disengage and fold up the safety pushbutton (2). Press
pushbutton "I" (1).
Switching off:
Fold up safety pushbutton (2). Press pushbutton "0"
(1).
After switching off, the machine runs on for
approx. 50 seconds.
Safety pushbutton:
In situations of danger, press the safety pushbutton to
switch the machine off.
Overload protection.
In case of continuous high load over a longer period of
time, the machine is switched off. After a cooling-down
period of approx. 15 minutes, the machine is ready for
operation again.
Working a workpiece (figures 3+4).
Make sure that the safety cover (14) is securely closed.
Check the gap clearance of the grinding rest and ensure
that both fastening screws (7) are tightened.
Check the tight seating of the spark guard (4).
Place the workpiece on the grinding rest and guide it
with both hands.
Extraction device
We recommend the use of an extraction device.
The machine can be connected via sleeve (16) to an
exhauster.
Noise emission values.
A-weighted emission
pressure power level
measured at the work-
place L
(re 20 μPa),
pA
in decibels
Measuring uncertainty
K
, in decibels
pA
Measured A-weighted
sound power level L
wA
(re 1 pW), in decibels
Measuring uncertainty
K
, in decibels
wA
Operating conditions
Speed (rpm)
Material
Dimension
Wire brush
REMARK: The sum of the measured emission value and
respective measuring inaccuracy represents the upper
limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the
corresponding product standard (see last page in this
Instruction Manual).
Repair and customer service.
Repairs may be carried out only by qualified per-
sons in conformity with the valid regulations.
For repairs, we recommend our FEIN customer service
centre, the FEIN authorised service centres and FEIN
agencies.
When the machine's power supply cable is damaged, it
must be replaced using a specially prepared power sup-
ply cable, available from your FEIN customer service
agent.
The current spare parts list of this machine can be found
on the Internet under www.fein.com.
Carry out the following maintenance regularly:
Blow out the cooling-air openings (9) of the
motor housing with compressed air.
Remove any deposits in the housing.
If required, you can change the following parts your-
self: application tools, spark guard
en
13
Idle
Sanding
78.5
91
4
4
87
98
2.5
2.5
3000
3000
– Stainless steel
Pipe, diame-
trer 42.4 mm
GRIT by Fein
0.35
Tabla de contenido
loading

Este manual también es adecuado para:

Grit gxe2v

Tabla de contenido