8.2.- General start up switch
18
Position 1 "OFF"
19
Position 2 "ON"
8.3.- "READY" Pilot light
The "READY" Pilot light (No.3b Fig.1) shows the user that the
equipment is ready to operate and at the programmed wor-
king temperature.
20
Red led
21
Green led
8.4.- Temperature sensor
Temperature sensor (No.04 Fig.1) is located at the outlet of the equipment.
It is not indicative of the temperature in the spray gun or application tool, as there will be a loss of
temperature due to connections, hoses, etc...
8.5.- Flow meter
The Flow meter (No.05 Fig.1) is used to electrically disable the resistance when the compressed
air consumption is insufficient for the proper operation of the equipment. Therefore, when the
spray gun or application tool does not consume compressed air, the resistance is disabled, once
again becoming enabled when consumption is resumed.
It is set at the factory to a value of approximately 150 Litres/minute as the minimum flow for its
operation.
It is strictly forbidden to manipulate the flow switch without prior con-
sultation with SAGOLA S.A.U. MANIPULATION OF THIS COMPONENT
MAY PUT THE PROPER OPERATION OF THE EQUIPMENT AT RISK.
Ignoring this warning may lead to the destruction of the resistance and thus the voiding of the
guarantee that covers the equipment.
Lights during auto tuning.
Lights during MV is indicated on SV display.
Lights during the time is indicated on SV display.
Lights during remaining time is indicated on SV display.
Shows the temperature unit under use.
Shows the unit being applied to values on SV screen during
the operation mode.
Equipment completely switched off
All circuits activated
Heating
Ready