H500UH (10-60V) ERROR CODES

HMI error code
41
10
11
42
80
86
70
76
46
Fault states
Over Current Error
Under Voltage Error
Over Voltage Error
Angle Sensor Error
Motor Phase Loss Error
Throttle Error
Torque Sensor Error
Brake Error
Motor Blocked
Solutions
Reduce the load on the motor by pushing stronger on the pedal or by reducing
the assist level.
Charge the battery pack using the battery charger.
Check battery. Switch off the system completely. If the problem persists, contact
your Decathlon workshop.
Switch off the system completely. If the problem persists, contact your Decath-
lon workshop.
Switch off the system completely. If the problem persists, contact your Decath-
lon workshop.
Check throttle is in position. If the problem persists, contact your Decathlon
workshop.
Switch off the system completely. If the problem persists, contact your Decath-
lon workshop.
Check Brake is in position. Switch off the system completely. If the problem
persists, contact your Decathlon workshop.
Switch off the system completely. If the problem persists, contact your Decath-
lon workshop.