Due to the small size of the sensor, the ATEX identification is located on a cable
flag.
Danger of an ignition source due to impermissible operating conditions,
connections, and parameters!
Operating the sensor under impermissible operating conditions can result in
an explosion.
1. Observe the permissible operating conditions, in particular the ambient
temperature and the mechanical protection for the device.
2. The ATEX sensor is only intended for complete installation in suitable T-
slots.
3. Note the limited temperature range for ATEX conditions.
4. Do not disconnect the plug connectors and the connecting cable from the
sensor if it is under voltage.
5. Only use approved M8 and M12 connecting cables approved by AVENTICS.
6. Observe the relevant Ex guidelines for installation, maintenance, and re-
pair, especially EN 60079-14.
The device will lose its Ex approval if these instructions are not complied with!

3 Scope of delivery

• 1x Operating instructions
• 1x Sensor
Variants with M8 and M12 plugs:
• Line with plug and removal protection clip

4 About This Product

The sensor is used to detect magnetic fields in explosive areas.

4.1 Product identification

Observe the product information on the product and packaging.
u

5 Assembly and commissioning

Fig. 1: Sensor porting configuration
1. Observe the Ex guidelines as per EN 60079-14.
2. The installation of electrical devices must be carried out in accordance with
applicable national regulations and performed or supervised by an electrical
specialist (in compliance with TRBS 1203 or equivalent).
3. Compare the information on the device with the information in the operating
instructions before installation.
Danger of explosion due to missing removal protection clip!
Exposed electrical connections are an ignition source in explosive areas!
With lines with M8 or M12 plugs, always assemble the supplied removal
u
protection clip over the plug-type connection.
Danger of injury if assembled under pressure or voltage!
Assembling when under pressure or voltage can
lead to injuries and damage to the product or system components.
1. Make sure the relevant system part is without voltage or pressure prior to
assembly.
2. Protect the system against being restarted.
1. Fit the sensor into the T-slot (any mounting orientation).
AVENTICS™ ST6 | R412024085-BAL-001-AE | English
WARNING
1
BN
+
3
BU
R
4
L
BK
WARNING
CAUTION
2. Install the sensor protected against mechanical impact and UV light (depend-
ing on the requirements/operating conditions).
3. Install lines with protection or provide for strain relief.

6 Maintenance

The product is maintenance-free. In case of technical problems, please contact
one of the addresses found under www.emerson.com/contactus.

7 Troubleshooting

Replace the sensor in the event of malfunctions or failure.
u

8 Disposal

Dispose of the product in accordance with the national regulations in your coun-
try.

9 Technical data

General
Voltage
Switching current
Ambient temperature
Cable length
ATEX
Zone 2
Zone 22
This section contains an excerpt of the most important technical data. Further
technical data can be found in the online catalog.

10 Declaration of conformity

The declaration of conformity can be found at the end of the instructions.
10 to 30 V DC
≤ 100 mA
–20°C to +50°C
R412022854
3 m
R412022856
5 m
R412022864
0.3 m/M12
R412022860
0.3 m/M8