WS-400 Series2 [BASE & CLEAR] - LS-400 Series2 GRAVITY SPRAY GUNS
EN
WARNING
OTHER PRECAUTIONS
DO NOT ENTER WORKING AREAS, WHERE ROBOTS, RECIPROCATORS, ETC. ARE USED, UNTIL
THEY HAVE BEEN TURNED OFF. Otherwise, they could cause injury.
ALWAYS USE NEUTRAL CLEANER: pH value shall be 6 to 8, otherwise could cause corrosion.
NEVER USE SPARE PARTS THAT ARE NOT ANEST IWATA ORIGINALS.
9. SETUP OF THE GUN
CAUTION
TO SUPPLY THE SPRAY GUN USE CLEAN AIR FILTERED THROUGH AIR DRYER AND AIR FILTER.
WHEN USING THIS GUN FOR THE FIRST TIME AFTER PURCHASE, CLEAN FLUID PASSAGES
AND REMOVE RUST PREVENTIVE OIL BY SPRAYING CLEANER.
FIRMLY FIX GRAVITY CUP TO SPRAY GUN, TO AVOID THAT DISCONNECTION OF IT, CAN
CAUSE BODILY INJURY.
1.
Flush fluid passages with a compatible cleaner.
Firmly connect an air hose to air nipple G1/4".
2.
Firmly connect the gravity cup to fluid nipple G1/4".
3.
Pour paint into container, adjust fluid output and as well as pattern width.
4.
10. HOW TO ADJUST AND HOW TO OPERATE
WS-400
Suggested air pressure is 2.0 bar (29 PSI) or less.
To achieve the recommended 0,7 bar (10 PSI) air pressure inside the air cap, first fully open the pattern
LS-400
adjustment. Then while pulling the trigger, set the air pressure at the inlet port to 1,8 bar (26
PATTERN ADJUSTMENT
FLUID OUTPUT ADJUSTMENT
Recommended paint viscosity differs according to paint property and painting conditions.
14 to 25 sec. / Ford cup#4 is recommended.
Set the spray distance from the gun to the workpiece, as near as possible within the range of 100-250 mm.
The spray gun should be held so that it is perpendicular to the surface of the workpiece at all times. Then, the gun
should move in a straight and horizontal line. Arcing the gun causes uneven painting.
11. SAFETY PRECAUTION DURING THE SET UP OF THE DIGITAL PRESSURE GAUGE DPG-1
TO AVOID TO PERMANENTLY DAMAGE THE DPG-1, NEVER TRY TO REMOVE OR DETACH IT
WARNING
WHEN THE SPRAY GUN IS PRESSURIZED.
USE EXCLUSIVELY SONY OR MURATA C1632 LITHIUM CELL.
AVOID ANY SITUATION THAT COULD EXPOSE THE BATTERY TO A SHORT-CIRCUIT.
6
PSI).
DIGITAL PRESSURE GAUGE
ADJUSTMENT
Digital
pressure
DISPLAY
Air Valve
Turn to adjust
WS-400 Series2 [BASE & CLEAR] - LS-400 Series2 GRAVITY SPRAY GUNS
12. DISASSEMBLY PROCEDURE OF THE DIGITAL PRESSURE GAUGE DPG-1
1
2
REVERSE THE PROCEDURE TO REASSEMBLY
13. HOW TO TO REPLACE BATTERY FROM DIGITAL PRESSURE GAUGE DPG-1
IMPORTANT: TO UNSCREW AND SCREW THE SCREWS FROM THE BATTERY COVER OF THE DIGITAL DEVICE, USE
EXCLUSIVELY THE SCREWDRIVER SUPPLIED WITH THE SPRAY GUN.
1
2
BATTERY COVER
HOUSING
Unscrew and remove the two screws
IMPORTANT:
TO
REMOVE
THE
from the battery housing cover.
COIN
BATTERY
FROM
THE
DIGITAL PRESSURE DEVICE DON'T
DISASSEMBLE ANY OTHER PARTS
EXCEPT THE ONLY BATTERY COVER
HOUSING AS SHOWN IN THE ABOVE
PICTURE.
3
3
1
3
2
Pull out in order, first the housing
cover and then the exhausted Coin
battery to be replaced.
EN
7