Farfisa EXHITO Serie Manual Del Usuario página 9

Teléfono para el sistema duo
Ocultar thumbs Ver también para EXHITO Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
EN
Function of buttons and meaning of signalling LED.
In stand-by
Button
- When the handset is on hook, it activates the electrical door
lock release of the last external station from which the call
was received.
- When the handset is off, activates conversation with the last
external station from which the call was received.
Only if kept pressed for more than 4 sec.
Button 2
Enables/disables the exclusion of all ringtones. When the
ringtones are excluded, the red LED flashes slowly.
Pressing the button for less than 1 sec, the function activated
depends on the address stored in the button, in detail:
- address 000, after picking up the handset you call an internal
station in the same flat as shown below;
- address of another flat or concierge unit, after picking up
the handset, it calls the address of that flat;
- address of an actuator, the actuator is activated/deactivated;
- address of an external unit you connect to the door unit
without having previously received the call If the handset is
on hook, the door lock is opened directly, if the handset is
off, you enter automatically in conversation.
Buttons
1, 3, 4, 5, 6
The function activated depends on the address stored in the
button, in detail:
- address 000, after picking up the handset you call an internal
station in the same flat as shown below;
- address of another flat or concierge unit, after picking up
the handset, it calls the address of that flat;
- address of an actuator, the actuator is activated/deactivated;
- address of an external unit you connect to the door unit
without having previously received the call If the handset is
on hook, the door lock is opened directly, if the handset is
off, you enter automatically in conversation.
Red LED
Flashes slowly
All ringtones are excluded.
Green LED
OFF
Yellow LED Permanently ON
Door open signalling
Example of using buttons for intercom service in the same flat.
All the buttons required for the service must be programmed with address 000.
2 intercommunicating intercoms.
100
100
000
001
000
CT0
CT1
3 intercommunicating intercoms.
100
100
000
001
000
000
CT0
CT1
When selecting the services to be activated with the buttons, priority must be
given to the intercom service in the same flat:
100
100
000
001
000
In the examples shown here:
- from the intercom with internal address 000, press button 1 to call intercpm with
- from intercom with internal address 001, press button 1 to call the intercom with
- from the intercom with internal address 002, it is no longer possible to call the
CT0
CT1
100
100
000
002
000
000
CT2
CT0
During call and conversation:
Activates the electrical door lock release of the external station
to which you are connected.
Only if kept pressed for more than 4 sec.
Enables/disables the exclusion of all ringtones.When the
ringers are muted, the red LED flashes as shown below.
Pressing the button for less than 1 sec, the only function that
can be executed is the activation/deactivation of a relay if the
address of a relay is stored.
The only function that can be executed is the activation/deacti-
vation of a relay if the address of a relay is stored.
Flashes slowly in call and is permanently on in conversation
when all ringtones are excluded.
Flashes slowly during the call and is permanently on in con-
versation
Permanently ON
Door open signalling.
If there are 2 intercoms in the flat, the first button of each intercom is reserved
for this service;
If there are 3 intercoms in the flat, the first 2 buttons of each intercom must be
reserved for this service;
with 7 intercoms, all 6 buttons on each intercom will be reserved for this service.
internal address 001;
internal address 000 or button 2 to call the intercom with internal address 002;
intercom with internal address 001 if button 2 is configured for a different service.
100
100
001
002
CT1
CT2
100
100
100
000
001
002
000
000
CT0
CT1
CT2
Mi 2401/1
- 9 -
loading

Este manual también es adecuado para:

Exhito ex362