TROUBLESHOOTING SYSTEM PROBLEMS
PROBLEM
REGENERATIONS
DO NOT HAPPEN
OUTFLOWING WATER
IS THE SAME QUALITY
AS THE INCOMING WATER
LACK OF
WATER PRESSURE
WATER LEAK IN
THE DRAINAGE OUTLET
THE CONTROLLER
TURNS CONSTANTLY
CONTINUOUSLY SENDING
WATER TO DRAINAGE
THE WATER SOFTENER
DOES NOT REGENERATE
HARD WATER LEAKS
OR HARD WATER
IN THE WATER SOFTENER
POSITION
Fault in the power supply.
Defective timer.
Power cut.
Open bypass valve.
Blocked drainage tube.
Leak inside the valve.
Obstructed connection hoses.
Saturated filter.
Air in the system.
Excessive backwash flow.
Damaged upper strainer.
Electronic controller failure.
Internal cable disconnection.
Blocked/damaged gears.
Leak inside the valve.
Tension failure in the backwash
or quick wash position.
The equipment is turned off.
The regeneration time is not
correct.
Broken counter.
Resins in bad condition.
Bypass valve is open.
There is no salt in the tank.
Obstructed injector.
There is not enough water in
the brine tank.
Dripping from the drainage
pipette.
Obstructed injector.
Not enough water in the brine
tank.
Dripping in the drainage pipette.
Dripping inside the valve.
The bypass mixer is too open.
Broken counter.
Check the electrical wiring.
Missing teflon.
Check the electrical wiring.
Close the bypass and/or mixing.
Unblock the drainage tube.
Clean / change the filter or the injector.
Change the valve body.
Clean tubes.
Replace pre-filter.
Completely remove the air from the tank.
Change the backwash regulator.
Replace the upper strainer.
Replace electronic controller.
Check internal wiring.
Repair gears.
Replace the valve body.
Turn the wheel manually to the "Service" position or close
the bypass until the power supply is re-established.
Check the power supply (fuses, connector, plug).
The stopcock or bypass are turned off.
Correct the time (see the programming section).
Check the status, repair or change it.
If the resin has been there for a long time, you must change it.
Close the bypass valve.
Make sure that there is tablet salt in the tank.
Clean or change the injector.
Check the time for water to fill the tank.
Check that the pipette is not broken or that the
O-ring is in poor condition.
Clean or change the injector.
Check the time for water to fill the tank.
Check that the pipette is not broken or that the
O-ring is in poor condition.
Check or change the valve body.
Adjust the bypass to reprogram it.
Check the state, repair or change it.
15