12.2 Markings and approvals
The following marks are available after positive testing of MAGNA3:
Mark
Description
Listed
Intertek - ETL Listed for USA and Canada
Conforms to
Certified to
USA and Canada
Applies to pumps with stainless steel pump housing (flange).
NSF/ANSI 372
13. Accessories
13.1 Grundfos GO
The pump is designed for wireless radio or infrared
communication with Grundfos GO. Grundfos GO enables setting
of functions and gives access to status overviews, technical
product information and actual operating parameters.
The radio communication between the pump and
Grundfos GO is encrypted to protect against misuse.
Grundfos GO is available in Apple App Store and Google Play.
Grundfos GO replaces the Grundfos R100 remote control. This
means that all products supported by R100 are now supported by
Grundfos GO.
You can use Grundfos GO for the following:
•
Reading of operating data.
•
Reading of warning and alarm indications.
•
Setting of control mode.
•
Setting of setpoint.
•
Selection of external setpoint signal.
•
Allocation of pump number to distinguish between pumps that
are connected via GENIbus.
•
Selection of function for digital input.
•
Generation of reports in PDF.
•
Assist function.
•
Multipump setup.
•
Display of relevant documentation.
For function and connection to the pump, see separate
installation and operating instructions for the desired type of
Grundfos GO setup.
62
ANSI/UL Std. 778
CAN/CSA C22.2 No. 108
13.2 Communication interface module, CIM
The pump can communicate via the wireless GENIair connection
or a communication module.
This enables the pump to communicate with other pumps and
with different types of network solutions.
The Grundfos communication interface modules enable the pump
to connect to standard fieldbus networks.
A communication interface module is an add-on communication
interface module.
The communication interface module enables data transmission
between the pump and an external system, for example a
building management system or SCADA system.
The communication interface module communicates via fieldbus
protocols.
The following communication interface modules are available:
Module
CIM 050
CIM 100
CIM 200
CIM 300
CIM 500
Motor Operated Water Pumps
Liquid Pumps
Fig. 65 Building management system, BMS, with four pumps
connected in parallel
A gateway is a device that facilitates the transfer of
data between two different networks based on
different communication protocols.
Fieldbus protocol
GENIbus
LonWorks
Modbus RTU
BACnet MS/TP
Ethernet
Product number
96824631
96824797
96824796
96893770
98301408