Shaking The Primary Filter; Emergency Stopping; Emptying The Dust Container; Plastic Bag (Class L Only) - Nilfisk T22PLUS Manual De Instrucciones

Ocultar thumbs Ver también para T22PLUS:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Shaking the primary filter

Figure 9-10
Depending on the vacuumed dust quantity and if the pointer
of the vacuum gauge switches from the green zone (3, Fig.
9) to the red zone (2, Fig. 9), turn the vacuum cleaner off and
shake the main filter with the knob (1, Fig. 10).
If the vacuum cleaner is equipped with electric filter shaker,
press and hold for a few seconds the button (6, Fig. 6). When
releasing the button, the filter shaker stops.
WARNING!
Stop the vacuum cleaner before shaking the filter.
Do not shake the filter while the vacuum cleaner is on,
as this could damage the filter itself.
Wait a few seconds before restarting the vacuum cleaner,
to allow the dust to settle. Replace the filter element if the
pointer still remains in the red zone (1, Fig. 9) even after the
filter has been shaken (consult the "Primary filter replacement"
paragraph).

Emergency stopping

Turn the main switch to "0" position.

Emptying the dust container

WARNING!
Before proceeding with these operations, turn off
the vacuum cleaner and remove the plug from the
power socket.
Check the class of the vacuum cleaner.
Before emptying the container it is advisable to shake the filter
(see "Shaking the main filter" paragraph).

Plastic bag (Class L only)

A plastic bag can be used to collect dust (see Fig. 11).
In this case, the vacuum cleaner must be equipped with
optional accessories [depressor (3) and grid (2), Fig. 11].

Versions for dusts harmful to health

Classes L, M, H suitable for vacuuming hazardous and/
or carcinogenic dust (H AA class)

Paper bag

Class M vacuum cleaners are supplied with the dust bag -
code 81584000 (Fig. 11).
Class M vacuum cleaners must always be used with this bag
installed. If the bag isn't installed or is installed incorrectly, this
could create health risks for persons exposed.
03/2017
T22 Plus - T40 Plus - T40W Plus

Safe Dust Bag

Class H vacuum cleaners are supplied with the dust bag -
code 4084001014 (Fig. 12).
Class H vacuum cleaners must always be used with this bag
installed. If the bag isn't installed or is installed incorrectly, this
could create health risks for persons exposed.

Replacement of hazardous dust bags

WARNING!
These operations can only be carried out by
trained and qualified personnel who must wear
adequate clothing, in compliance with the laws in
force.
Take care not to raise dust when this operation is
carried out. Wear a P3 protective mask.
In case of hazardous and/or harmful dust, use
only the bags recommended by the manufacturer
(see "Recommended spare parts").
The container and/or bag must only be disposed
of by qualified personnel and in compliance with
the laws in force.
Replacement of the paper bag (Fig. 12)
Close the inlet by using the relevant cap (1).
Release the dust container.
Remove the bag and close it with the relevant cap as
shown in figure 11.
Insert a new bag, making sure the bag inlet is sealed.
Replace the dust container in the vacuum cleaner.
How to replace the safe bag for class H vacuum
cleaners (Fig. 13)
Remove and put the vacuum hose in a safe and dust-
free place.
Close the inlet by using the relevant cap (1).
Release the dust container.
Close the Safe Bag by pulling the "guillotine" (2) seal.
Close the plastic bag hermetically using the relevant
band (3).
Use the sticky tape (4) to close the bottom of the plastic
bag.
Remove the relevant connection (5) of the bag from the
inlet.
Insert a new safe bag, making sure the bag inlet is
sealed.
Wrap the plastic bag around the dust container external
wall.
Replace the dust container in the vacuum cleaner.
WARNING!
In case of ATEX industrial vacuum cleaners, ensure
that the dust container lock lever is not covered by
the plastic bag, and that the container conductivity is
checked.
Set the dust container into the vacuum cleaner again.