TROUBLESHOOTING

Check the indicators and follow the instructions below when there is a malfunction.
If a problem is not resolved or the symptoms do not improve, contact an authorized Honda
servicing dealer.
Charge Level Check Button
Indicator
ALERT
ERROR
Flash
Illuminate
Flash
ALERT Indicator
Possible Cause
Charge
Level
Problem was
detected.
Problem was
4 indicators
detected.
flash
(Overvoltage
protection)
Problem was
1 indicator
detected.
flashes
(Low voltage
protection)
Problem with the
specified device or
Battery Charger, or
malfunction in the
Battery Pack was
detected.
Malfunction was
detected.
ERROR Indicator
ALERT ERROR
Charge Level Indicator
Solution
Remove all equipment connected to the
Battery Pack, wait for about 5 minutes and
press the Charge Level Check Button.
• When the ALERT indicator does not flash,
the Battery Pack can be used normally.
After following the instructions for the
Battery Pack problem, connect the specified
device and check if it works properly.
• When the device works, the Battery Pack
can be used normally.
After following the instructions for the
Battery Pack problem, connect the Battery
Charger and check if the charging starts
properly.
• When the charging starts, the Battery
Pack can be used normally.
Remove all equipment connected to the
Battery Pack, wait until all indicators turn off
and press the Charge Level Check Button.
• When the ERROR indicator does not
illuminate, the Battery Pack can be used
normally.
Check that there is no foreign material
around the Battery Pack. Connect the
specified device or Battery Charger.
• When the ERROR indicator illuminates,
there is a problem with the specified
device or Battery Charger.
Battery Pack is dead.
7