GB
Operating Instructions Flat-bed lift table FLEXILIFT-FLUNDER
9. I
/
NSPECTION
MAINTENANCE
Observe safety regulations
What?
Check oil level
Oil change
Bleed the air out of the
hydraulics system
Check condition and leak
tightness of the hydraulics
system
Inspection of the me-
chanical connections
Check foot protection strip For every start-up
Cleaning
Maintenance intervals for use in single-shift operation.
Halve the maintenance intervals for multiple shift operation.
Oil recommendation: VITAM GF 22 (Aral)
When?
2 weeks after com-
missioning/
monthly
annually
monthly
2 weeks after com-
missioning/
annually
2 weeks after com-
missioning/
annually
daily
Description
Lower lift table completely
Oil level up to top edge of filler neck.
Lower lift table completely.
Disconnect hydraulic hose.
Unscrew coupling sleeve from the hose.
Undo the filler neck threaded connection.
Hold the hose in a collecting container.
Pump the oil out of the tank (Press "Raise" button)
Move lift table against mechanical end stop several times
Press "Raise" button for 2-3 seconds.
Check hydraulics lines, valves, piping, hoses, couplings,
threaded connections
Tighten threaded connections showing traces of oil.
Replace any damaged parts.
Bleed the hydraulics system my moving the lift table against the
mechanical end stop several times.
Replace all hydraulics hoses every 6 years.
General visual inspection and functional check of all mechanical
connections.
If the protection strip is not in perfect working order, the lift
table must be shut down
9