GB
Operating Instructions Flat-bed lift table FLEXILIFT-FLUNDER
6.1. Removing the lift table from the pallet
Attention Do not lift the lift table from the pallet in its lowered condition
Lift scissor could unfold or the splined roller yoke could fall out of its seating.
Connect drive unit temporarily.
Connect drive unit to the lift table using hydraulic quick-release coupling.
Plug mains plug (SCHUKO or CEE) into the socket
Raise lift table using operating switch
lift the raised lift table on the narrow side (hose connection side), remove from
the pallet.
Now lift the other side and remove the pallet.
6.2. Commissioning movable lift tables
1. Connect supply lines
Power supply using mains plug with corresponding fuses.
AC motor 240 V - Schuco:
Three-phase version CEE plug:
2. Attach accessories (e.g. ramp)
3. Make electrical connection
4. Depressurise hydraulic line by pressing "Lower"
5. Connect drive unit using hydraulics quick-release coupling (5)
Coupling
Platform connection
When the top lift position is reached, do not press the
Short, jerking raising and lowering is prohibited. This can damage the machine
»
Raise
min. 16 A
10 A
Attach coupling sleeve
(hose) to coupling connec-
tor (lift table)
«
.
Base connection
»
«
Raise
button any more.
Connect coupling
sleeve and coupling
connector with each
other.