Maintenance Checklist; Product Specifications; Torque Values - Matrix MD-AP MEDICAL Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48

MAINTENANCE CHECKLIST

ACTION
Clean Upholstery
1
Inspect Cables
2
Clean Guide Rods
Inspect Hardware
Inspect Frame
Clean Machine
Clean Grips
1
Lubricate Guide Rods
3
Upholstery & Grips should be cleaned with a mild soap
1
and water or a non-ammonia based cleaner.
Cables should be inspected for cracks or frays and immediately replaced if present.
2
If excessive slack exists cable should be tightened without lifting the head plate.
3
Guide rods should be lubricated with Teflon based lubricant. Apply the
lubricant to a cotton cloth and then apply up and down the guide rods.
WARRANTY
For North America, please visit www.matrixfitness.com for warranty
information along with warranty exclusions and limitations.
All manuals and user guides at all-guides.com
FREQUENCY
Daily
Daily
Monthly
Monthly
Bi-Annually
As Needed
As Needed
As Needed

PRODUCT SPECIFICATIONS

Max Training Weight
Max User Weight
Product Weight
Weight Stack
Effective Resistance
Add-On-Weight (optional)
Overall Dimensions
(L x W x H)*
* Ensure a minimum clearance width of 0.6 meters (24") for access to and
passage around MATRIX strength equipment. Please note, 0.91 meters (36") is
the ADA recommended clearance width for individuals in wheelchairs.

TORQUE VALUES

M10 Bolt (Nyloc Nut & Flowdrill)
M8 Bolts
M8 Plastic
M6 Bolts
Pad Bolts
71.6 kg / 158 lbs.
159 kg / 350 lbs.
174 kg / 384 lbs.
68 kg / 150 lbs.
34 kg / 75 lbs.
Qty 4, 1 lb. effective resistance
increments
108 x 125 x 228 cm /
43" x 50" x 90"
77 Nm / 57 ft -lbs
25 Nm / 18 ft-lbs
15 Nm / 11 ft-lbs
15 Nm / 11 ft-lbs
10 Nm / 7 ft-lbs
7
Tabla de contenido
loading

Tabla de contenido